FLUKE BC430/830 BC430 Line Voltage Adapter/Battery Charger

User Manual for the Fluke BC430 Line Voltage Adapter/Battery Charger - Page 82

For BC430/830.

PDF File Manual, 93 pages, Read Online | Download pdf file

BC430/830 photo
Loading ...
Loading ...
Loading ...
Industrial ScopeMeter®
Specifications
75
Amperes (AMP)
with current clamp
Ranges ............................................................ same as VDC, VAC, VAC+DC, or PEAK
Scale Factors .................................................. 0.1 mV/A, 1 mV/A, 10 mV/A, 100 mV/A, 400 mV/A, 1 V/A, 10 mV/mA
Accuracy ......................................................... same as VDC, VAC, VAC+DC, or PEAK (add current clamp uncertainty)
with iFlex clamp
Ranges ............................................................ 20 A/division
Maximum Current ............................................ 75 A @ 40 Hz to 300 Hz
Frequency derating: I * F <22 500 A*Hz @ 300 Hz to 3000 Hz
Accuracy ......................................................... ± (1.5 % + 10 counts) @ 40 Hz to 60 Hz
± (3 % + 15 counts) @ 60 Hz to 1000 Hz
± (6 % + 15 counts) @ 1000 Hz to 3000 Hz
Temperature (TEMP) with optional temperature probe
Range .................................................................. 200 °C/div (200 °F/div)
Scale Factor ........................................................ 1 mV/°C and 1 mV/°F
Accuracy.............................................................. as VDC (add temp. probe uncertainty)
Decibel (dB)
0 dBV................................................................... 1V
0 dBm (600 Ω /50 Ω) ........................................... 1 mW referenced to 600 Ω or 50 Ω
dB on ................................................................... VDC, VAC, or VAC+DC
Full Scale Reading .............................................. 1000 counts
Crest Factor (CREST)
Range .................................................................. 1 to 10
Accuracy.............................................................. ±(5 % + 1 count)
Full Scale Reading .............................................. 90 counts