Hikvision DS-PDD12P-EG2-WB Wireless Dual-Tech Detector

Product's Documents

Below are documents related to this product, you can read online or download:
User Manual Specification Installation Instruction
DS-PDD12P-EG2-WB photo

User Manual

This is the main product document for model DS-PDD12P-EG2-WB. Additionally, the document applies to other Hikvision models: DS-PDD12P-EG2-WE

The file format is pdf, 7 pages, you can download this manual here .

background
©2020 Hangzhou Hikvision Digital Technology Co., Ltd. All rights reserved.
About this Manual
The Manual includes instruc�ons for using and managing the Product. Pictures, charts, images and all other informa�on hereina�er are for descrip�on and explana�on only. The informa�on contained in the Manual is subject to change,
without no�ce, due to firmware updates or other reasons. Please find the latest version of this Manual at the Hikvision website (h�ps://www.hikvision.com/).
Please use this Manual with the guidance and assistance of professionals trained in suppor�ng the Product.
and other Hikvision's trademarks and logos are the proper�es of Hikvision in various jurisdic�ons. Other trademarks and logos men�oned are the proper�es of their respec�ve owners.
Disclaimer
TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THIS MANUAL AND THE PRODUCT DESCRIBED, WITH ITS HARDWARE, SOFTWARE AND FIRMWARE, ARE PROVIDED “AS IS” AND “WITH ALL FAULTS AND ERRORS”. HIKVISION MAKES
NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, MERCHANTABILITY, SATISFACTORY QUALITY, OR FITNESS FOR A PARTICULAR PURPOSE. THE USE OF THE PRODUCT BY YOU IS AT YOUR OWN RISK. IN NO EVENT WILL
HIKVISION BE LIABLE TO YOU FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT DAMAGES, INCLUDING, AMONG OTHERS, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, OR LOSS OF DATA, CORRUPTION OF
SYSTEMS, OR LOSS OF DOCUMENTATION, WHETHER BASED ON BREACH OF CONTRACT, TORT (INCLUDING NEGLIGENCE), PRODUCT LIABILITY, OR OTHERWISE, IN CONNECTION WITH THE USE OF THE PRODUCT, EVEN IF HIKVISION HAS BEEN
ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSS.
YOU ACKNOWLEDGE THAT THE NATURE OF INTERNET PROVIDES FOR INHERENT SECURITY RISKS, AND HIKVISION SHALL NOT TAKE ANY RESPONSIBILITIES FOR ABNORMAL OPERATION, PRIVACY LEAKAGE OR OTHER DAMAGES RESULTING FROM
CYBER-ATTACK, HACKER ATTACK, VIRUS INSPECTION, OR OTHER INTERNET SECURITY RISKS; HOWEVER, HIKVISION WILL PROVIDE TIMELY TECHNICAL SUPPORT IF REQUIRED.
YOU AGREE TO USE THIS PRODUCT IN COMPLIANCE WITH ALL APPLICABLE LAWS, AND YOU ARE SOLELY RESPONSIBLE FOR ENSURING THAT YOUR USE CONFORMS TO THE APPLICABLE LAW. ESPECIALLY, YOU ARE RESPONSIBLE, FOR USING THIS
PRODUCT IN A MANNER THAT DOES NOT INFRINGE ON THE RIGHTS OF THIRD PARTIES, INCLUDING WITHOUT LIMITATION, RIGHTS OF PUBLICITY, INTELLECTUAL PROPERTY RIGHTS, OR DATA PROTECTION AND OTHER PRIVACY RIGHTS. YOU
SHALL NOT USE THIS PRODUCT FOR ANY PROHIBITED END-USES, INCLUDING THE DEVELOPMENT OR PRODUCTION OF WEAPONS OF MASS DESTRUCTION, THE DEVELOPMENT OR PRODUCTION OF CHEMICAL OR BIOLOGICAL WEAPONS, ANY
ACTIVITIES IN THE CONTEXT RELATED TO ANY NUCLEAR EXPLOSIVE OR UNSAFE NUCLEAR FUEL-CYCLE, OR IN SUPPORT OF HUMAN RIGHTS ABUSES.
IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW, THE LATER PREVAILS.
1
Appearance
2
Enrollment
Note: The enrollment progress will be completed in 3 to 10 seconds normally, and the maximum enrollment dura�on is 3 minutes.
1
Enroll the Peripheral Locally
1. Log in to the APP Store, download and install Hik-Pro.
2. Power on the security control panel.
3. Log in the APP and tap the icon "+" . Scan the QR code or input the control panel serial No. to add the control panel.
1. In the APP, tap the "Enrollment Mode" bu�on on the control panel page to make the control panel enter the enrollment status.
2. Loosen the screw and remove rear panel.
3. Power on the peripheral, and it will be automa�cally enrolled to the control panel.
This product and - if applicable - the supplied accessories too are
marked with "CE" and comply therefore with the applicable harmonized
European standards listed under the EMC Direc�ve 2014/30/EU, RE
Direc�ve 2014/53/EU, the RoHS Direc�ve 2011/65/EU.
replacement of a ba�ery with an incorrect type that can defeat a safeguard (for example, in the case of some lithium
ba�ery types);
– disposal of a ba�ery into fire or a hot oven, or mechanically crushing or cu�ng of a ba�ery, that can result in an
explosion;
– leaving a ba�ery in an extremely high temperature surrounding environment that can
result in an explosion or the leakage of flammable liquid or gas; and
– a ba�ery subjected to extremely low air pressure that may result in an explosion or the leakage of flammable liquid
or gas
2012/19/EU (WEEE direc�ve): Products marked with this symbol
cannot be disposed of as unsorted municipal waste in the European
Union. For proper recycling, return this product to your local supplier
upon the purchase of equivalent new equipment, or dispose of it at
designated collec�on points. For more informa�on see:
www.recyclethis.info
2006/66/EC (ba�ery direc�ve): This product contains a ba�ery that cannot be disposed of as unsorted municipal
waste in the European Union. See the product documenta�on for specific ba�ery informa�on. The ba�ery is marked
with this symbol, which may include le�ering to indicate cadmium (Cd), lead (Pb), or mercury (Hg). For proper
recycling, return the ba�ery to your supplier or to a designated collec�on point. For more informa�on see:www.recy-
clethis.info
CAUTION
RISK OF EXPLOSION IF BATTERY
IS REPLACED BY AN INCORRECT
TYPE.
REPLACEMENT OF A BATTERY
WITH AN INCORRECT TYPE THAT
CAN DEFEAT A SAFEGUARD.
CAUTION
CHEMICAL BURNING DANGER
DO NOT SWALLOW THE
BATTERY
KEEP NEW AND USED
BATTERIES AWAY FROM THE
CHILDREN.
IF YOU THINK BATTERIES MIGHT
HAVE BEEN SWALLOWED OR
PLACED INSIDE ANY PART OF
THE BODY, SEEK IMMEDIATE
MEDICAL ATTENTION.
CAUTION
DISPOSE OF USED BATTERIES
ACCORDING TO THE INSTRUC-
TIONS AND LOCAL REGULATION.
Hangzhou Hikvision Digital Technology CO.,Ltd. No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China
xxxx
Enrollment Mode
CAUTION
IF THE BATTERY COMPARTMENT
DOES NOT CLOSE SECURETLY,
STOP USING THE PRODUCT AND
KEEP IT AWAY FROM CHILDREN.
Indicator
Bracket Tamper Port
Ba�ery
Tamper Switch
Power Switch
1
7 T i m e s
Wireless Dual-Tech Detector
DS-PDD12P-EG2-WB/WE
EN50131-1:2006+A1:2009+A2:2017
EN 50131-2-4:2008
EN 50131-5-3:2017
Security Grade(SG) 2
Environmental Class(EC) II
Cer�fied by Telefica�on
background
1. Check Signal Strength
Enter the signal checking mode by opera�ng on the control panel. Trigger the detector.
Solid Green for 3 s - Strong Signal
Solid Orange for 3 s - Medium Signal
Solid Red for 3 s - Weak Signal
Red light flashes for 3S - Failure
2. Check the installa�on environment
Note: Hold the tamper bu�on, and make the device power off and then power on for re-enrollment.
3
Installa�on
2
Enroll the Peripheral with QR and serial No.
1. In the APP, tap the icon "+"and scan the QR code or serial No. on the peripheral.
2. Loosen the screw and remove rear panel.
3. Power on the peripheral, and it will be automa�cally enrolled to the control panel.
Hangzhou Hikvision Digital Technology CO.,Ltd. No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China
HIK-PRO
xxxx
Device
Signal Strength Test
2
7 T i m e s
background
3. Install the Detector
Note: The addi�onal force shall be equal to three �mes the weight of the equipment but not less than 50N. The equipment
and its associated moun�ng means shall remain secure during the installa�on. A�er the installa�on, the equipment,
including
any associated moun�ng plate, shall not be damaged.
with Screws
a. Knock out the screw holes on the rear panel.
with the Sponge Tape
Paste the device on the wall with sponge tape.
Hangzhou Hikvision Digital Technology CO.,Ltd. No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China
b. Secure the rear panel on the wall with four screws.
3
background
Bracket Installaon
Ceiling Bracket Fi�ng (Non EN compliant)
Wall Bracket Fi�ng
4
Test
Hangzhou Hikvision Digital Technology CO.,Ltd. No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China
Detector zones and planes
The zones and plans of the PIRCAM are shown below.
4
10m 12m1m 2m 4m 6m 8m
10m 12m1m
2.4m
2m 4m 6m 8m
10m
12m
1m
2m
4m
6m
8m
85.9°
(a) Detec�on Range
52 zones
4 planes
background
Hangzhou Hikvision Digital Technology CO.,Ltd. No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China
The detector will enter the walk test mode (3 minutes) a�er being enrolled.
Trigger the detector within the detec�on range.
If the LED indicator turns blue, the installa�on posi�on is properly. If the LED indicator is s�ll off, adjust the posi�on of the detector.
3min
5
Forma�ng
Hold the tamper switch for 8 s and power the device on at the same �me. The red LED flashes 3 �mes when the forma�ng
opera�on is completed.
5
6
Set up with App
Link the detector to the zone.
On the device list page, tap the AX PRO and then log in to the device (if required) to enter the Area page.
Tap Device, and tap the zone.
You can view the device status including temperature, ba�ery status, signal strength, etc.
Tap the bu�on in the upper right corner to enter the Se�ngs page.
Func�on Descrip�on
Zone Type
Stay Arm Bypass
Chime
Silent Alarm
Slide to green to enable the chime.
Slide to green to make the zone keep
silent while alarm is triggered.
Select the zone type of the detector such as
the instant zone, the 24-hour zone, etc.
Slide to green to bypass the zone from
stay arming.
Forbid Bypass on Arming
Slide to green to forbid the zone with
fault to be bypassed automatically when arming.
background
7
Opera�on Cau�on and Device Maintenance
- All the electronic opera�on should be strictly compliance with the electrical safety regula�ons, fire preven�on
regula�ons and other related regula�ons in your local region.
- Do not drop the device or subject it to physical shock, and do not expose it to high electromagne�sm radia�on.
Avoid the equipment installa�on on vibra�ons surface or places subject to shock (ignorance can cause equipment
damage).
- Please make sure that the power has been disconnected before you wire, install or dismantle the device.
- If smoke, odors or noise rise from the device, turn off the power at once and unplug the power cable, and then
please contact the service center.
- Do not drop the device or subject it to physical shock, and do not expose it to high electromagne�sm radia�on.
Avoid the equipment installa�on on vibra�ons surface or places subject to shock (ignorance can cause equipment
damage).
- Do not place the device in extremely hot (refer to the specifica�on of the device for the detailed opera�on
temperature), cold, dusty or damp loca�ons, and do not expose it to high electromagne�c radia�on.
Hangzhou Hikvision Digital Technology CO.,Ltd. No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China
6
Func�on Descrip�on
Swinger limit ac�va�ons
Set the limit �mes of swinger ac�vi�on.
LED
Turn On/Off the LED.
Polling Rate
Set the interval of heartbeat.
Signal Strength Test
Enter the test mode, and view the LED
indica�on.
Detec�on Zone Test
Enter the test mode, and start walk test.
Bypass
Slide to green to bypass the zone.
Double Knock
Slide to green to make the zone alarm
with double knock.
Cross Zone
If the alarm triggered in both of the linked
zones within the set �me, two alarm
messages will be reported.
Sounder Delay Time Set the delay �me. The sounder will be triggered
immediately or a�er the set �me.
Link Camera
Link with a camera for intruder verification.
Find Me
Tap Find Me to make peripherals find the zone.
background
8
Specifica�on
Hangzhou Hikvision Digital Technology CO.,Ltd. No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China
7
Model
DS-PDD12P-EG2-WB/WE
Detecon
Performance
Detecon Method Passive Infrared,Microwave
Sensor Model SFG321-711
Detecon Range 12m
Detecon Angle 85.
Detecon Zones 52
Detectable Speed 0.3 to 2m/s
Sensivity Auto,High,Pet
Pet Immunity 30Kg
White Light Filter 6500lux
Microwave Frequency
24GHz(24.1524.25GHz)
Digital Temperature Compensaon Support
Creep Zone Protecon Support
Feature
Digital Processing Support
Sealed Op�cs Support
Tamper Protecon Front,Rear
Environment Temperature Indicator Support
Signal Strength Indicator Support
Interface
Power Switch Power Up Enrolling
LED Indicator Green(PIR), Red(Microwave), Blue(Alarm)
Transmission
Transmission Technology Tri-X Wireless
Transmission Method Two-Way RF Wireless
Transmission Frequency 433MHz/868MHz
Transmission Security AES-128 Encryp�on
Transmission Range(Free Space) 1.2 Km(433MHz)/1.6 Km(868MHz)
Frequency Hopping Support
Enrolling Method Power up,Remote ID,QR Code
Electrical
Characteriscs
Power Supply Baery Powered
Baery Type CR123A × 2
Typical Voltage 3V
Standard Baery Life 5 Years
General
Operaon Temperature -10 °C to 55 °C (14 °F to 131 °F)
Storage Temperature -20 °C to 60 °C (-4 °F to 140 °F)
Operaon Humidity 10% to 90%
Dimension(WxHxD) 65.5mm × 103mm × 48.5mm
- The device for indoor use shall be kept from rain and moisture.
Exposing the equipment to direct sun light, low ven�la�on or heat source such as heater or radiator is forbidden (ignorance
can cause fire danger).
- Do not aim the device at the sun or extra bright places. A blooming or smear may occur otherwise (which is not a
malfunc�on however), and affec�ng the endurance of sensor at the same �me.
- Improper use or replacement of the ba�ery may result in hazard of explosion. Replace with the same or equivalent type
only. Dispose of used ba�eries according to the instruc�ons provided by the ba�ery manufacturer.
- Do not expose the device to the corrosive gas. Otherwise the equipment damage may occur.
- Do not expose the device to the explosive situa�on.

Specifications

Hikvision DS-PDD12P-EG2-WB Questions and Answers