Loading ...
Loading ...
Loading ...
![](https://files.manualsfile.com/54086283-0217x-001/bga.png)
AXISQ1961-TEThermalCamera
Configureyourdevice
2.SetadurationforTriggerafter.Thevalueindicatesthetimethatmustpassbeforeanemailissent.
3.TurnonTriggerondarkimagestodetectifthelensissprayed,covered,orrenderedseverelyoutoffocus.
Addanemailrecipient:
4.GotoSystem>Events>Recipientsandaddarecipient.
5.Typeanamefortherecipient.
6.SelectEmail.
7.Typeanemailaddresstosendtheemailto.
8.Thecameradoesn’thaveit’sownemailserver,soithastologintoanotheremailservertosendmails.Fillintherestofthe
informationaccordingtoyouremailprovider.
9.Tosendatestemail,clickTest.
10.ClickSave.
Createarule:
11.GotoSystem>Events>Rulesandaddarule.
12.Typeanamefortherule.
13.Inthelistofconditions,underVideo,selectTampering.
14.Inthelistofactions,underNotications,selectSendnoticationtoemailandthenselecttherecipientfromthelist.
15.Typeasubjectandamessagefortheemail.
16.ClickSave.
Detectasmolderingre
Withthethermometryfunctionality,youcandetecttemperaturechangesinthemonitoredarea.Theearlyredetection
BETA
app
ltersuninterestingmovingobjects,tominimizefalsealarms.
Inthisexample,thecameramonitorsthetemperatureinapileofdebris.Theappltersworkvehiclesthatmoveinfrontofthepile.
Ifthepileitselfbecomessohotthataremightstart,thecamerashowsatextoverlay.
Thisexampleexplainshowto:
•Setupatemperaturedetectionareathatmonitorsifthetemperatureinthearea’swarmestpartexceeds50°C(122°F).
•Createarulethatshowsatextoverlayifthetemperatureexceedsthepresetthreshold.
Setupatemperaturedetectionarea
1.GotoThermometry>Temperaturedetectionandaddanarea.
2.InName,typePile.
3.TurnonUsearea.
4.InTemperatureinthearea,selectWarmestspot.
5.SelectAboveandtype50(122)inthetemperatureinputeld.
Addoverlaytext
1.GotoVideo>Overlaysandclick
.
10