Loading ...
Loading ...
Loading ...
22 INSTALLATION
2 Press the adapter duct c onto the blower
housing and secure it to the base of the dryer
as shown.
3 Insert the 4" (10.2 cm) elbow d through the
rear opening and press it onto the adapter
duct. Be sure that the male end of the elbow
faces down through the hole in the bottom of
the dryer. Secure it in place with duct tape.
Attach the cover plate
e to the back of the
dryer with the included screw.
Venting the Dryer
WARNING
Gas dryers MUST exhaust to the outdoors.
To reduce the risk of fire, combustion, or
accumulation of combustible gases, DO NOT
exhaust dryer air into an enclosed and
unventilated area, such as an attic, wall, ceiling,
crawl space, chimney, gas vent, or concealed
space of a building.
To reduce the risk of fire, DO NOT exhaust the
dryer with plastic or thin foil ducting.
Do not exceed the recommended duct length
limitations noted in the chart. Failure to follow
these instructions may result in extended drying
times, fire or death.
Do not crush or collapse ductwork.
Do not allow ductwork to rest on or contact
sharp objects.
If connecting to existing ductwork, make sure it
is suitable and clean before installing the dryer.
Venting must conform to local building codes.
Use only 4-inch (10.2 cm) rigid, semi-rigid or
flexible metal ductwork inside the dryer cabinet
and for venting outside.
The exhaust duct must be 4 inches (10.2 cm) in
diameter with no obstructions. The exhaust duct
should be kept as short as possible. Make sure to
clean any old ducts before installing the new
dryer.
Rigid, semi-rigid or flexible metal ducting is
recommended for use between the dryer and
the wall. All non-rigid metal transition duct must
be UL-listed. Use of other materials for transition
duct could affect drying time.
DO NOT use sheet metal screws or other
fasteners which extend into the duct that could
catch lint and reduce the efficiency of the
exhaust system. Secure all joints with duct tape.
Ductwork is not provided with the dryer. You
should obtain the necessary ductwork locally.
The vent hood should have hinged dampers to
prevent backdraft when the dryer is not in use.
The total length of flexible metal duct must not
exceed 8 ft. (2.4 m).
When pushing the dryer into the installed
position, do not crush or collapse ductwork.
Ductwork
a
b
c
d
e
Wall Cap Type
No. of
90°
Elbows
Maximum length
of 4-inch
diameter rigid
metal duct
Recommended 0 65 ft. (19.8 m)
1 55 ft. (16.8 m)
2 47 ft. (14.3 m)
3 36 ft. (11.0 m)
4 28 ft. (8.5 m)
a
a
a: 4 ‘’ (10.2 cm)
en-us_main.book.book Page 22 Tuesday, December 12, 2023 12:59 PM
Loading ...
Loading ...
Loading ...