Measurement Menu
The Measurement Menu has settings for the calculation and display of
radiometric temperature measurement data related to the thermal images.
These settings include the Range (Auto and Manual Level and Span
adjustment), Emissivity, Background, Transmission, Spot Temperatures,
Markers, and Center Box.
Range
Range (level and span) is set to automatically adjust or is set for manual
adjustment. To choose between automatic or manual level and span, do the
following:
1. Push .
2. Push / to highlight Measurement.
3. Push or to view the menu.
4. Push / to highlight Range.
5. Push or to view the menu.
6. Push / to toggle between the Auto and Manual ranging.
7. Push to set.
8. Push:
to set the change and go back to the live view.
or to set the change and go back to the previous menu.
to cancel the change and go back to the live view.