5200245-01H
SPECIFICATIONS
Model FDI32R
Gas Type Natural Gas Propane Gas
Ignition Battery Ignitor Battery Ignitor
Input Rating
32,000 Btu/Hr 32,000 Btu/Hr
Pressure Regulator Setting 4" W.C. 9" W.C.
Inlet Gas Pressure* (inches of water)
(*for purposes of input adjustment)
Maximum 9.5" Maximum 14"
Minimum 5" Minimum 11"
Heater Dimensions (HxWxD) •
33.27" × 36.38" × 18.38"
Carton Dimensions (HxWxD) •
35.85" × 40.19" × 20.49"
Stove Weight 88.2 lbs
Shipping Weight 98.5 lbs
QUALIFIED INSTALLING AGENCY
Only a qualied agency should install and
replace gas piping, gas utilization equipment
or accessories, and repair and equipment ser-
vicing. The term “qualied agency” means any
individual, rm, corporation, or company that
either in person or through a representative
is engaged in and is responsible for:
a) Installing, testing, or replacing gas piping
or
b) Connecting, installing, testing, repairing, or
servicing equipment; that is experienced in
such work; that is familiar with all precautions
required; and that has complied with all the
requirement of the authority having jurisdiction.
PRODUCT FEATURES
SAFETY PILOT
This heater has a pilot with an Oxygen Deple-
tion Sensing (ODS) safety shuto󰀨 system. The
ODS/pilot shuts o󰀨 the heater if there is not
enough fresh air.
BATTERY IGNITION SYSTEM
This heater is equipped with an electronic
battery control system. This system requires
one AAA battery (provided).
2 GAS OPTIONS AVAILABLE
Your heater is equipped to operate on either
propane or natural gas. The heater is shipped
from the factory ready for connecting to pro-
pane. The heater can easily be changed to
natural gas by having your qualied installer
follow the instructions on page 10 and the
markings on the heater.
LOCAL CODES
Install and use heater with care. Follow all
local codes. In the absence of local codes,
use the latest edition of The National Fuel
Gas Code, ANSI Z223.1/NFPA 54*.
*Available from:
American National Standards Institute, Inc.
25 West 43rd Street
New York, NY 10036
National Fire Protection Association, Inc.
1 Batterymarch Park
Quincy, MA 02269-9101
This heater is designed for vent-free operation.
State and local codes in some areas prohibit
the use of vent-free heaters.
State of Massachusetts: The installation
must be made by a licensed plumber or gas
tter in the Commonwealth of Massachusetts.
Sellers of unvented propane or natural
gas-red supplemental room heaters shall
provide to each purchaser a copy of 527
CMR 30 upon sale of the unit.
In the State of Massachusetts the gas
cock must be a T-handle type. The State
of Massachusetts requires that a exible
appliance connector cannot exceed three
feet in length.