STEP 5: Gas Valve
a. Remove control knobs.
STEP 6: Reconnect Gas and Electrical Supply
Leak testing of the range shall be conducted according to the installation instructions provided with
the range.
Before operating the range after the gas conversion, always check for leaks with a soapy water
solution or other acceptable method in at gas connections installed between the gas inlet pipe of the
range, gas regulator, and the manual shut-off valve.
26
b. Using a flat screwdriver, adjust main burner bypass jets toward to 1/4 circle for LP until the flame
is normal. For 9,000btu and 15,000btu burners, please refer to fig.1, which is in the center of valve
axis. For 20,000btu burners, please refer to fig.2, which is in the left side of valve axis.
Use soapy solutions to check for leakage on all joints.
fig.1
fig.2
PLEASE NOTE: If the bypass jets screw is tighten too much, the igniter will go ON when burner is
set to minimum because the gas outlet is too low.