20
Capacitance measurement
1� Remove power from the circuit being tested� Turn the rotary function switch to ,
press the “FUNC�” key 3 times until “nf” appears on the display�
2� Connect the black test lead to the COM terminal and the red test lead to the INPUT
terminal�
3� Connect the probes across the circuit or (capacitance) component to be tested�
4� View the reading on the display�
Warning
To avoid electrical shock when testing capacitance in a circuit, make sure the power to
the circuit is turned o and all capacitors are discharged.
When measuring small capacitors, turn on the relative value (REL) to subtract the
residual capacitance value of the meter and the conductor when the test probe is open�
When measuring a capacitance greater than 100uF, it will take a long time to measure
correctly�
Overload protection: 250V