13
inside the Jaw
1� Turn the rotary switch to the correct current setting (60/600 , 1000 )� “DC” appears
on the display� Press the “FUNC�” button, AC is shown on the display
2� If measuring DC current, wait for the display to stabilize and then push to zero
the Meter
3� Open the Jaw by pressing the Jaw Release and insert the conductor into the Jaw�
4� Close the Jaw and center the conductor using the alignment marks�
5� View the reading on the display
►Do not use the current clamp to surround more than one conductor.
►If the supply and return conductors (e.g. L and N) are measured, the currents will
cancel each other out and no measurement will be displayed� The cables of household
appliances usually contain L and N conductors� A cable separator is required to measure
with the current probe�
►If several supply conductors are measured, the currents add up.