KAIWEETS HT208D 1000A AC/DC Inrush Clamp Meter T-RMS 6000 Counts for AC/DC

User Manual - Page 12

For HT208D.

PDF File Manual, 32 pages, Read Online | Download pdf file

Loading ...
Loading ...
Loading ...
8
When an electrical device is rst powered on, inrush current is the surge or momentary
burst of current that ows into it.
AC current measurement with “VFD” function (Variable
Frequency Drive Filtering)
The VFD mode eliminates high frequency noise in voltage measurements by means
of a low-pass filter� The VFD mode is designed for variable frequency drive (VFD)
measurements� This mode is always active for AC measurements
Turn the knob and select proper range(60/600 or 1000 ), press the key until
the VFD” symbol is displayed�
Note: Please do not use VFD function to verify the presence of dangerous voltage or
current, which may exceed the indicated value�
AC voltage measurement with “VFD” function
Turn the knob to or , press key until the “VFD” symbol is displayed�
Note: Please do not use VFD function to verify the presence of dangerous voltage or