For the Installer
5. AIR DISTRIBUTION
VF0051
TOP PORTS UNITS SIDE PORTS UNITS
FRONT
FRONT
FRESH AIR
TO BUILDING
STALE AIR
FROM
BUILDING
STALE AIR
TO OUTSIDE
FRESH AIR
FROM OUTSIDE
FRESH AIR
TO BUILDING
STALE AIR
FROM
BUILDING
STALE AIR
TO OUTSIDE
FRESH AIR
FROM
OUTSIDE
6. INSTALLATION
Inspect the exterior of the unit for shipping damage. Make sure that there is no damage to the door, ports, power cord, etc.
6.1 LOCATING THE UNIT
Choose an appropriate location for the unit.
Within an area of the house where the ambient temperature is between 10°C (50°F)
and 50°C (122°F) (basement, furnace room, closet, etc.)
Away from living areas (dining room, living room, bedroom), if possible
So as to provide easy access to the interior of the unit, for maintenance
Close to an exterior wall, so as to limit the length of the insulated flexible duct to and from
the unit
Away from hot chimneys and other fire hazards
Allow for a standard 3-prong grounding outlet within 3 feet of the unit
Close to a drain. If no drain is close by, use a pail to collect run-off
Slightly bend all 4 hooks located on both sides of the unit in order to hang it to ceiling joists with
the 4chains and springs provided. See illustration aside.
VD0242
Make sure the unit is level.
CAUTION
Before installing this unit, please take the time to carefully read page 2 of this guide to ensure it is installed safely
and and properly.