Thermal Presence Detector User Manual
9
Chapter 4 People Number Management
People number management is used to detect the people number in a predefined area. When the
number is abnormal, the device triggers alarms.
4.1 Set People Number Management Rule
Draw the detection area and set detection rule for people number management.
Before You Start
Go to Configuration System Maintenance VCA Resource Type, and select Temperature
Measurement + People Number Management.
Steps
1. Go to Configuration People Number Management Rule.
2. Click to add a region and enter a region name.
Note
Click to clear the selected region.
3. Click , and click on the live image to draw a region.
4. Set detection parameters for the region.
People Number OSD
Check the item to display the real-time people number of the region on live image.
Drag the yellow OSD frame to adjust the display position.
Alarm Times Per Exception
Check the item to enable the function and enter a desired Times.
The Times stands for the maximum times of uploading alarm information for one exception
incident. If the parameter is not set, the device uploads the alarm information continuously
until the exception disappears.
Alarm Interval
It is the minimum time interval for the device to upload alarms for a different exception
incident. If the interval between two exceptions is less the set value, the second exception
will not trigger alarm uploading.
First Alarm Delay
It is the time the device waits before it triggers alarm and uploads information.
This parameter helps to filter out the interference caused by people moving around the edge
of the detection region.
5. Optional: Check Number of People Exception Detection, and set the Alarm Trigger Condition.