3. Press Bus from the bottom menu
and choose the CAN serial bus.
Define Inputs
4. Press Define Inputs from the lower
menu.
5. From the side menu choose the
CAN Input inputs and the signal
type.
CAN Input
CH1~CH2
Signal Type
CAN_H, CAN_L, Tx, Rx.
Note
The Sample Point soft-key indicates the sampling
position of each bit. This parameter is fixed.
Bit Rate
The Bit Rate menu sets the bit rate of the bus. The
bit rate is usually tied to the bus length.
6. Press Bit Rate from the bottom
menu and set the bit rate.
Bit Rate
10kbps, 20kbps, 50kbps, 125kbps,
250kbps, 500kbps, 800kbps, 1Mbps
LIN Serial Bus Interface
The local interconnect network (LIN) bus is a single wire interface.
Panel operation
1. Connect the bus signal (LIN Input) to one of the
oscilloscope’s analog or digital channels.
Connect the ground potential to one of the
probes’ ground clip if you are using the analog
channels or to the ground connector of the
Digital card if you are the using digital
channels.