Bosch WQG245A0GB Heat pump tumble dryer

Manual - Page 15

For WQG245A0GB.

PDF File Manual, 48 pages, Read Online | Download pdf file

WQG245A0GB photo
Loading ...
Loading ...
Loading ...
Installation and connection en
15
3. Push the water drain hose as far
as it will go into the connecting
piece.
4. Empty the condensation container.
→"Emptying the condensation
container", Page32
5. Remove the stopper from the un-
derside and insert it in the re-
cess in the top ⁠.
6. Insert the condensation container.
→"Inserting the condensation con-
tainer", Page33
7. Connect the appliance to the water
outlet.
→"Water outlet connection types",
Page15
Tip:To collect condensation in the
condensation container again (e.g. if
you change where the appliance is
located), carry out these steps in re-
verse order.
Water outlet connection types
ATTENTION!
In the event of a blocked or covered
outlet, accumulated wastewater can
flow back into the appliance.
Before operating the appliance, en-
sure that the wastewater drains
away quickly and eliminate any
blockages.
Drainage into a
siphon.
Secure the con-
nection point with
a (12-22 mm)
hose clamp.
Secure the water
outlet hose with
a hose guide at
a height of at
least 80 cm and
no more than
100 cm.
Note:You can
use the Y-distrib-
utor →Page28
to connect the
water drain hose
of an additional
appliance, such
as a washing
machine, to the
same siphon out-
let.
Drainage into a
wash basin.
Push the water
drain hose fully
through the el-
bow and secure
it using fixing ma-
terial.
Secure the elbow
at a height of no
more than 100
cm.
Drainage into a
gully.
Push the water
drain hose fully
through the el-
Loading ...