Notes for installer
26
Maximum permis-
sible total duct
length
Adequate room ventilation must be ensured during operation.
Minimum inside duct diam-
eter (sheet metal ducting)
Maximum permissible total duct
length
Exhaust air
PRI 214
PRI 217
2¾" (70mm) 16'4⅞" (5m)
3⅛" (80mm) 65'7⅜" (20m)
3½" (90mm) 104'11⅞" (32m)
4" (100mm) 131'2¾" (40m)
Once the machine has been successfully installed and con-
nected, replace all the external parts that were removed.
Optional accessories
Mounting the
base (optional)
Mounting the optionally available base can raise the machine by
4"(100mm).
Dismantle the mounting flaps on the left and right sides.
Unscrew the screw-on feet by the maximum amount
(>2⅜"(60mm)).
Hold the side columns with a suitable aid and remove the screw-on
feet.
Mount the screw-on feet into the base and push the base under the
column.
Screw the base to the base plate of the machine.