Stiebel Eltron TEMPRA 15 PLUS Electric Tankless Whole House Water Heater

OPERATION AND INSTALLATION - Page 7

For TEMPRA 15 PLUS. Also, The document are for others Stiebel Eltron models: TEMPRA® 12 B, TEMPRA® 15 B, TEMPRA® 20 B, TEMPRA® 24 B, TEMPRA® 29 B, TEMPRA® 36 B, TEMPRA® 12 PLUS, TEMPRA® 15 PLUS, TEMPRA® 20 PLUS, TEMPRA® 24 PLUS, TEMPRA® 29 PLUS, TEMPRA® 36 PLUS

PDF File Manual, 17 pages, Read Online | Download pdf file

TEMPRA 15 PLUS photo
Loading ...
Loading ...
Loading ...
WWW.STIEBEL-ELTRON-USA.COM TEMPRA & TEMPRA PLUS | 7
ENGLISH
INSTALLATION
ELECTRICAL CONNECTION
8.1.2 Tempra 15, 20, 24 B / Tempra 15, 20, 24 Plus
OFF
ON
OFF
ON
OFF
ON
OFF
ON
26_02_02_0568
CKT 1
CKT 2
Tempra 15, 20 or 24 B/Plus: These units require two independent
circuits. Use two supply cables protected by two separate double
pole breakers.
8.1.3 Tempra 29, 36 B / Tempra 29, 36 Plus
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
26_02_02_0568
26_02_02_0881
CKT 1
CKT 2
CKT 3
Tempra 29 or 36 B/Plus These units require three independent circuits.
Use three supply cables protected by three separate double pole
breakers.
8.2 Circuit Connection
Please refer to the technical data table for the correct wire and
circuit breaker size. In all cases, make sure that the unit is properly
grounded.
1. Cut the electrical connection cable to length and strip.
15˝ (380mm)
26_02_02_0893
The wire must be fed through the knock-outs located between
the hot and cold water connections (See 8.1, “Circuit Layout”,
pg. 6). The "live" wires must be connected to the slots on the
terminal block marked L1 and L2. The ground wire must be con-
nected to slot marked with the ground symbol (See 13.5,Wiring
Diagrams, pg. 13 ).