Hikvision DS-2XC6225G0-L Bullet Underwater Network Camera

User Manual - Page 137

For DS-2XC6225G0-L.

PDF File Manual, 188 pages, Read Online | Download pdf file

DS-2XC6225G0-L photo
Loading ...
Loading ...
Loading ...
Network Camera User Manual
136
disappears from the region for 10s.
9. Drag the slider to set the sensitivity value.
Sensitivity: Range [1-100]. It stands for the percentage of the body part of an
acceptable target that leaves the pre-defined region.
Sensitivity = 100 S
1
/S
T
*100
S
1
stands for the target body part that leaves the pre-defined region. S
T
stands
for the complete target body.
Example: if you set the value as 60, a target is possible to be counted as a
removed object only when 40 percent body part of the target leaves the region.
Note: The Sensitivity of the detection is supported by certain models. Refer to
actual display for details.
10. Repeat the above steps to configure other regions. Up to 4 regions can be set.
You can click the Clear button to clear all pre-defined regions.
11. Click Arming Schedule to set the arming schedule.
12. Click Linkage Method to select the linkage methods.
13. Click Save to save the settings.
VCA Configuration
Behavior Detection
The function detects a series of suspicious behavior, and certain linkage methods will
be enabled if the alarm is triggered.
Loading ...
Loading ...
Loading ...