Chapter 3 Terminal and Wiring
3.1 Terminal Descripon
The power source should be qualied and meet limited power source or PS2 requirements
according to IEC 60950-1 or IEC 62368-1 standard.
Main Unit Terminals
Figure 3-1 Main Unit Terminals
Table 3-1 Descripons of Terminals and Interfaces
No. Interface Descripon
A1 NC1 Door Lock Relay Output (NC)
A2 NO1 Door Lock Relay Output (NO)
A3 COM Common Interface
A4 NC2 Door Lock Relay Output (NC)
A5 NO2 Door Lock Relay Output (NO)
A6 GND Grounding
A7 12 V IN/OUT1
The power output is 12 V, 500mA.
When the device is powered by PoE, the 12V
IN/OUT interface can supply power to the lock.
A8 GND Grounding
B1 AIN2 For the access of Door Magnec 2