Zline RAINDBG30 30 Inch Freestanding Induction Range with 4 Elements, 4.0 cu. ft. Convection

Owners Guide - Page 10

For RAINDBG30.

PDF File Manual, 20 pages, Read Online | Download pdf file

RAINDBG30 photo
Loading ...
Loading ...
Loading ...
12
13
ELECTRIC POWER RATING
VAC 240
Plug NEMA 14-50P (50 AMP plug)
Amps 45
Hz 60
W 6200
L2 (red)
N (white)
G (green)
L1 (black)
L2 (red)
N (white)
G (green)
L1 (black)
cable from
power supply
Four-Wire Connection
Receptacle
NEMA 14-50R
ELECTRICAL GROUNDING
This oven is equipped with a four-prong plug for protection against shock hazard
and should be plugged directly into a properly grounded receptacle. Do not cut or
remove the prong from this plug.
Disconnect electrical power at the circuit breaker box or fuse box
before installing the appliance.
Provide appropriate ground for the appliance. Use copper conductors
only.
No attempt should be made to operate the appliance during power
failure.
WARNING
Label all wires prior to disconnecting when servicing controls. Wiring errors can
cause improper and dangerous operation. Verify proper operation after servicing
INSTALLATION
Power Rating & Electrical Connection
Check your local code for which of the options below should be used in grounding
the receptacle power supply connections.
OPTION 1 - FOUR WIRES CONNECTION:
1. Connect the LI receptacle terminal to the incoming BLACK electrical supply wire
(Ll-hot wire).
2. Connect the L2 receptacle terminal to the incoming RED electrical supply wire
(L2-hot wire).
3. Connect the NEUTRAL receptacle terminal to the incoming NEUTRAL (WHITE)
electrical supply wire.
4. Connect the GROUND receptacle terminal to the incoming GROUND (GREEN)
electrical supply wire.
OPTION 2 - THREE-WIRES CONNECTION:(THIS OPTION IS ONLY AVAILABLE
IN THE UNITED STATES)
1. Connect the LI receptacle terminal to the incoming BLACK electrical supply wire
(Ll-hot wire).
2. Connect the L2 receptacle terminal to the incoming RED electrical supply wire
(L2-hot wire).
3. Connect the NEUTRAL with the GROUND receptacle terminal to the incoming
NEUTRAL (WHITE) electrical supply wire
DO NOT USE EXTENSION CORDS WITH THIS APPLIANCE AS IT MAY RESULT
IN FIRE, ELECTRIC SHOCK OR OTHER type of PERSONAL INJURY.
The appliance is equipped at the factory with an electric supply cord set 4 wires
type with ring terminals (LI, L2, N, Ground) suitable for range use UL/CSA listed
type SRDT/DRT 4x6AWG (LI, L2, N, G) rated 300V, 50A with fused plug type
NEMA 14-50P; cable length 4.9 ft.
In case the supply cord set must be replaced, it shall be replaced with an
identical set having the same technical specifications.
INSTALLATION
Power Rating & Electrical Connection