PERLICK RESIDENTIAL UNDERCOUNTER CUBELET ICE MAKER PRODUCT MANUAL
32 | perlick.com/residential
PREPARING THE APPLIANCE FOR PERIODS OF NON-USE
PREPARING THE APPLIANCE FOR PERIODS
OF NON-USE
During extended periods of non-use, extended absences, or in
sub-freezing temperatures, follow the instrucons below. When
the appliance is not used for two or three days under normal
condions, it is sucient to move the control switch to the
“OFF” posion.
Only qualied service technicians should
service the appliance.
During extended periods of non-use,
extended absences, or in sub-freezing temperatures, follow the
instrucons below to reduce the risk of costly water damage.
1) Move the control switch to the “OFF” posion.
To reduce the risk of electric shock, do not
touch the control switch or plug with damp hands.
2) Close the water supply line shut-o valve, then open
the water supply line drain valve. See Fig. 23.
3) Allow the line to drain by gravity.
4) Move the control switch to the “DRAIN” posion.
5) Allow the water system to drain for 1 minute.
6) Aach a compressed air or carbon dioxide supply to
the water supply line drain valve.
7) Move the control switch to the “ICE” posion.
8) Blow the water supply line out using the compressed
air or carbon dioxide supply.
9) Close the water supply line drain valve.
10) Move the control switch to the “OFF” posion, then
unplug the appliance from the electrical outlet.
11) Remove the screws securing the upper rear panel,
then remove it (See Fig. 27).
DANGER
!
WARNING
DANGER
!
12) Remove the clamp securing the reservoir outlet hose
to the reservoir. Disconnect the reservoir outlet hose
from the reservoir.
13) Aach a compressed air or carbon dioxide supply to
the reservoir outlet hose.
14) Plug the appliance back in, then move the control
switch to the “DRAIN” posion.
15) Blow out the reservoir outlet hose using the
compressed air or carbon dioxide supply.
16) Move the control switch to the “OFF” posion, then
unplug the appliance from the electrical outlet.
17) Reconnect the reservoir outlet hose to the reservoir,
then secure with the clamp. Make sure all hoses are
connected and secure.
18) Replace the rear panel in its correct posion.
19) Clean the storage bin by using a neutral cleaner. Rinse
thoroughly aer cleaning.
Fig. 27
Upper Rear Panel
Clamp
Reservoir
Outlet
Hose
Reservoir
Overow Hose