FLUKE 1664FC US Installation Multifunction Tester, 500 V, insulation pre-test

User Manual for the Fluke 1664FC US Installation Multifunction Tester, 500 V, insulation pre-test - Page 66

For 1664FC US.

PDF File Manual, 95 pages, Read Online | Download pdf file

1664FC US photo
Loading ...
Loading ...
Loading ...
1662/1663/1664 FC
Users Manual
60
Auto Start
Auto Start enables faster testing and is a power-up option. When the Tester
detects mains voltage in the loop/line or RCD tests, the test starts automatically
without pushing .
Loop Impedance Test with 10 mA RCD
For a Loop impedance measurement in a 10 mA RCD circuit, the tripping time
RCD test is recommended. Use a nominal test current of 10 mA and the factor
x ½ for this test.
If the fault voltage is <25 V or 50 V, dependent on the local requirement, the
loop is good. To calculate the loop impedance, divide the fault voltage by 10
mA (Loop impedance = fault voltage x 100).
1.888.610.7664 sales@GlobalTestSupply.com
Fluke-Direct.com
Loading ...
Loading ...
Loading ...