Hikvision DS-KH6350-TE1 KH6 Series IP-Based Indoor Station

Operation User Manual - Page 34

For DS-KH6350-TE1.

PDF File Manual, 36 pages, Read Online | Download pdf file

DS-KH6350-TE1 photo
Loading ...
Loading ...
Loading ...
Table A-1 Table A
Roung Path Twisted Pair :
24 AWG (0.2
mm
2
)
Twisted Pair :
20 AWG (0.5
mm
2
)
Twisted Pair :
18AWG (0.8
mm
2
)
Twisted Pair :
16AWG (1
mm
2
)
Parallel lines
(0.5 mm
2
to
0.8 mm
2
)
DS-KAD706-S-
DS-KAD706
Transmission
Distance ≤ 60
m
Transmission
Distance ≤ 60
m
Transmission
Distance ≤ 60
m
Transmission
Distance ≤ 50
m
Transmission
Distance ≤ 35
m
DS-KAD706-
DS-KAD706
Transmission
Distance ≤ 60
m
Transmission
Distance ≤ 60
m
Transmission
Distance ≤ 60
m
Transmission
Distance ≤ 50
m
Transmission
Distance ≤ 35
m
DS-KAD706-
DS-KD8003-
IME2
Transmission
Distance ≤ 35
m
Transmission
Distance ≤ 60
m
Transmission
Distance ≤ 60
m
Transmission
Distance ≤ 50
m
Transmission
Distance ≤ 35
m
DS-KAD706-
DS- KH6320-
WTE2
Transmission
Distance ≤ 35
m
Transmission
Distance ≤ 100
m
Transmission
Distance ≤ 100
m
Transmission
Distance ≤ 100
m
More
parameters in
Table B
Roung Path Parallel lines: 24
AWG (0.2 mm
2
)
Parallel lines: 20
AWG (0.5 mm
2
)
Parallel lines: 18
AWG (0.8 mm
2
)
Parallel lines: 16
AWG (1 mm
2
)
DS-KAD706- DS-
KH6320-WTE2
Transmission
Distance ≤ 50 m
Transmission
Distance ≤ 100 m
Transmission
Distance ≤ 100 m
Transmission
Distance ≤ 100 m
Device Installaon
Installaon environment (temperature, moisture etc.) need to follow requirements in
specicaon or power output can be eected.
Power consumpon of modular door staon (main module and sub modules) should be less
than 12W. Please reach local technical support if you are not sure about power consumpon of
each module. Door
staon should be connected to CH6 of the video/audio distributor. If
modular door staon is connected to any terminal of CH1 to CH5, up to 3 sub modules can be
connected.
Indoor
staon should be connected to any terminal of CH1 to CH5 of the video/audio distributor.
Up to 15 video/audio distributor can be cascaded. If more distributors are needed, you should
cascade network switch
supporng 1000 Mbps. The whole 2-wire system can have up to 500
devices.
Power supply must be
cered by Hikvision.
Indoor staon needs to use rmware released aer October, 2019.