2-Wire
Model DS-KD8003-
IME2
DS-KD-DIS DS-KD-KP DS-KD-M /
Quanty 1 1 2 2 /
Power 4 W 2.5 W 2 W 1.6 W Total: 10.1 W
Because 10.1 W ≤ 16 W, we can support powering this device through KAD706 channel 6 or
KAD704 channel 4.
2-Wire
Model DS-KD8003-IME2 DS-KD-M DS-KD-KK /
Quanty 1 1 12 /
Power 4 W 0.8 W 9.6 W Total: 14.4 W
Because 14.4 W ≤ 16 W, we can support powering this device through KAD706 channel 6 or
KAD704 channel 4.
Wire
Tesng Standards
When there are mulple cores in one parallel line, only one pair of closed cores are allowed to
transmit signal. It is not allowed to use
mulple pair of cores in one cable to transmit signal.
When using parallel lines, it is suggested to use those with shielding layer. If dual core or mulple
core parallel lines without shielding layer are routed, stability of signal transmission can be
eected. You need to run a test before installaon.
Impedance of twist pair in network cable are over 42 Ω/100 m, so network cable cannot
transmit enough power to indoor
staon. Network cable is not allowed to use during
installaon.
Strong electricity and weak electricity cannot be wired in the same route, they need to be wired
separately and the distance should be more than 0.5 meter.