Loading ...
Loading ...
Loading ...
![](https://files.manualsfile.com/42151158-wj-nx310kg/bg16.png)
22
Time and polarities of the ALARM/CONTROL connector
Terminal name Active Time Remarks
Alarm input 100 ms or more N.O.: L active
N.C.: H active
Alarm reset input 100 ms or more L active
Emergency recording input 100 ms or more L active
External recording mode
switching input
100 ms or more L active
Network error output At an error occurrence until the period selected for "Error
output duration" has passed*
L active
HDD error output/
Recording error output
At an error occurrence until the period selected for "Error
output duration" has passed*
L active
Camera error output At an error occurrence until the period selected for "Error
output duration" has passed* or the camera reset
L active
Recorder error output At an error occurrence until the period selected for "Error
output duration" has passed*
L active
Alarm output The set time on the setup menu L active
General-purpose input/output
(when set to input)
100 ms or more For N.O.: L active
For N.C.: H active
General-purpose input/output
(when set to output)
At an error occurrence until the period selected for "Error
output duration" has passed *
L active
* The error output duration is configured on the "Advanced setup" menu - the "Maintenance" page - "System setup" of the setup
menu. (☞ Operating Instructions)
Note:
• During "L active (Low active)", the logic will be implemented when the voltage level of signal is low.
• During "H active (High active)", the logic will be implemented when the voltage level of signal is high.
4
Connections (continued)
Loading ...
Loading ...
Loading ...