19
How to use the terminals of the ALARM/CONTROL
The ALARM/CONTROL connectors on the back is used when connecting an external device such as a sensor that outputs alarm
signals or when installing an external alarm device such as a buzzer or a lamp outside.
Insert the unarmored cable into the terminal plug and then mount it on the ALARM/CONTROL connector on the back.
* The cable should be a single or twisted wire with AWG 26~16 and an exposed length of 9 mm {11/32 inches}.
ALARM/CONTROL connector B
B12
A12
B1
A1
Cable connections
Loosen the screw of the desired
terminal on the terminal plug.
Tight the screw when the cable is
fully inserted into the terminal hole.
Mount the terminal plug with the
cable connected on the ALARM/
CONTROL connector socket on the
back.
Terminal plug (12 pin)ALARM/CONTROL connector socket
Pin array
Pin No. Signal Operation Remarks
A1
Alarm reset input Canceling the alarm display Non-voltage make contact input
+3.3 V pull-up Approx. 23 kΩ
A2
Emergency recording
input
Starting emergency recording signal input
A3
External recording
mode switching input
Changeover to the external recording mode by the
signal input
A4
Network error output A signal will be output upon detection of a discon-
nected Ethernet link or network protocol error
Open collector output
24 V DC max., –200 mA max.
A5
Camera error output Signal output upon detection of a camera error
A6
HDD error output/
Recording error output
Signal output upon detection of an HDD error or
recording error in this product
A7
Recorder error output Signal output upon detection of a recorder error
A8
General-purpose
input/output 1
Input and output can be assigned in the setting
menu of this product.
• The default value of the setting menu is "Not set"
Input:
Non-voltage make-contact input
3.3 V pull-up approx. 23 kΩ
Output:
Open collector output
Max. 24 V DC, -200 mA
A9
+5 V output +5 V output +5 V±0.5 V, 200 mA max.
A10
Signal ground
A11
General-purpose
input/output 2
Same as the General-purpose input/output 1
Same as the General-purpose
input/output 1
A12
General-purpose
input/output 3
4
Connections (continued)
Loading ...
Loading ...
Loading ...