Loading ...
Loading ...
Loading ...
![](https://files.manualsfile.com/42151158-wj-nx310kg/bg13.png)
19
How to use the terminals of the ALARM/CONTROL
The ALARM/CONTROL connectors on the back is used when connecting an external device such as a sensor that outputs alarm
signals or when installing an external alarm device such as a buzzer or a lamp outside.
Insert the unarmored cable into the terminal plug and then mount it on the ALARM/CONTROL connector on the back.
* The cable should be a single or twisted wire with AWG 26~16 and an exposed length of 9 mm {11/32 inches}.
ALARM/CONTROL connector B
B12
A12
B1
A1
Cable connections
②
①
① Loosen the screw of the desired
terminal on the terminal plug.
② Tight the screw when the cable is
fully inserted into the terminal hole.
③ Mount the terminal plug with the
cable connected on the ALARM/
CONTROL connector socket on the
back.
③
Terminal plug (12 pin)ALARM/CONTROL connector socket
Pin array
Pin No. Signal Operation Remarks
A1
Alarm reset input Canceling the alarm display Non-voltage make contact input
+3.3 V pull-up Approx. 23 kΩ
A2
Emergency recording
input
Starting emergency recording signal input
A3
External recording
mode switching input
Changeover to the external recording mode by the
signal input
A4
Network error output A signal will be output upon detection of a discon-
nected Ethernet link or network protocol error
Open collector output
24 V DC max., –200 mA max.
A5
Camera error output Signal output upon detection of a camera error
A6
HDD error output/
Recording error output
Signal output upon detection of an HDD error or
recording error in this product
A7
Recorder error output Signal output upon detection of a recorder error
A8
General-purpose
input/output 1
• Input and output can be assigned in the setting
menu of this product.
• The default value of the setting menu is "Not set"
Input:
Non-voltage make-contact input
3.3 V pull-up approx. 23 kΩ
Output:
Open collector output
Max. 24 V DC, -200 mA
A9
+5 V output +5 V output +5 V±0.5 V, 200 mA max.
A10
Signal ground
A11
General-purpose
input/output 2
Same as the General-purpose input/output 1
Same as the General-purpose
input/output 1
A12
General-purpose
input/output 3
4
Connections (continued)
Loading ...
Loading ...