![](https://files.manualsfile.com/32563963-cd9381-hntv/bg17f.png)
VIVOTEK
User's Manual - 383
servername
-1
© 2022 VIVOTEK INC. All Right Reserved
239
PARAMETER
VALUE
DESCRIPTION
function
focus,
auto,
scan,
stop,
positioning,
irisopen,
irisenable,
resetfocus
focus – Move focus motor
auto – Perform auto focus
scan – Perform focus scan
stop – Stop current operation
positioning – Position the motors
resetfocus – reset focus position to default
irisopen – Fully open iris. It will maintain fully open iris
status until sending function=irisenable cgi.
irisenable – return back to user setting status of iris.
direction
direct,
forward,
backward
Motor’s moving direction.
It works only if function= focus.
position
<motor_start> ~
<motor_end>
Motor’s position.
It works only if function=focus and direction=direct.
<motor_start> : remote_focus_zoom_motor_start or
remote_focus_focus_motor_start,
<motor_end> : remote_focus_zoom_motor_end or
remote_focus_focus_motor_end replied from
"function=getstatus"
steps
1 ~ 30
Motor’s moving steps.
It works only if function=focus and direction=forward or
direction=backward.
* Motor will stop when it reaches to <motor_start> or
<motor_end>.
* This parameter is for additional fine-
tune, the value is from
1 to 30.
iris
N/A
Open iris or not.
It works only if function=auto or function=scan.
Syntax:
(for query API)
http://<servername>/cgi-bin/admin/remotefocus.cgi?channel=<value>&[function=<value>]