Hikvision DS-2TD1117-3/PA Thermal Network Turret Camera

User Manual - Page 60

For DS-2TD1117-3/PA.

PDF File Manual, 96 pages, Read Online | Download pdf file

DS-2TD1117-3/PA photo
Loading ...
Loading ...
Loading ...
Set the alarm temperature and pre-alarm temperature. E.g., select Alarm Rule as Above
(Average Temperature), set the Pre-Alarm Temperature to 50 °C, and set the Alarm
Temperature to 55 °C. The device pre-alarms when its average temperature is higher than
50 °C and alarms when its average temperature is higher than 55 °C.
Filtering Time
It refers to the
duraon me aer the target temperature reaches or exceeds the pre-alarm
temperature/alarm temperature.
Tolerance Temperature
Set the tolerance temperature to prevent the constant temperature change to
aect the
alarm. E.g., set tolerance temperature as 3 °C, set alarm temperature as 55 °C, and set pre-
alarm temperature as 50 °C. The device sends pre-alarm when its temperature reaches 50 °C
and it alarms when its temperature reaches 55 °C and only when the device temperature is
lower than 52 °C will the alarm be cancelled.
Pre-Alarm Output and Alarm Output
When the temperature of target exceeds the pre-alarm or alarm threshold, it triggers the pre-
alarm or alarm output of the connected device.
Area's Temperature Comparison
Select two areas and set the comparison rule, and set the temperature
dierence threshold.
The device alarms when the temperature dierence meets the seng value.
5.
Refer to
Set Arming Schedule for seng scheduled me. Refer to Linkage Method Sengs for
seng linkage method.
6.
Oponal: Shield certain area from being detected. Refer to Set Temperature Measurement
Shield Region for detailed sengs.
7.
Oponal: Set the osite pre-alarm/alarm specially during o-hours when there are less causes
of false alarms. You can set the lower alarm temperature to improve the
eciency of quick
alarm.
Note
The funcon varies according to dierent camera models.
1) Click .
2) Check Enable Osite.
3) Set the
osite pre-alarm/alarm and follow step 4~5 to adjust the pre-alarm/alarm
temperature and arming schedule during working hours.
Note
The same parameters and linkage method apply to the two kinds of pre-alarm/alarm, only the
threshold temperature and arming schedule vary.
Osite Pre-Alarm Temperature
Thermal Network Camera User Manual
46
Loading ...
Loading ...
Loading ...