Steps
1.
Go to Conguraon → Event → Event and Detecon → Alarm Input .
2.
Select an Alarm Input NO. and click to set alarm input.
3.
Select Alarm Type from the dropdown list. Edit the Alarm Name.
4.
Check Enable Alarm Input Handling.
5.
Refer to Set Arming Schedule for seng scheduled me. Refer to Linkage Method Sengs for
seng linkage method.
6.
Click Copy to... to copy the sengs to other alarm input channels.
7.
Click Save.
8.1.4 Set Excepon Alarm
Excepon such as network disconnecon can trigger the device to take corresponding acon.
Steps
1.
Go to Conguraon → Event → Basic Event → Excepon .
2.
Select Excepon Type.
HDD Full
The HDD storage is full.
HDD Error
Error occurs in HDD.
Network Disconnected
The device is oine.
IP Address Conicted
The IP address of current device is same as that of other device in the network.
Illegal Login
Incorrect user name or password is entered.
Abnormal Restart
The device restarts abnormally.
3.
Refer to Linkage Method Sengs for seng linkage method.
4.
Click Save.
8.1.5 Set Audio Excepon Detecon
Audio excepon detecon funcon detects the abnormal sound in the scene, such as the sudden
increase/decrease of the sound intensity, and some certain acons can be taken as response.
Steps
1.
Go to Conguraon → Event → Event and Detecon → Audio Excepon Detecon .
2.
Select one or several audio excepon detecon types.