Click One-touch Calibraon. When calibraon for all scenes is complete, click
Stop Calibraon to exit.
Single Scene
Calibraon
If certain scenes in panoramic channel have bad stching eect, it is
recommended to use Single Scene Calibraon to calibrate these scenes.
Select a scene. Use the PTZ control buons to adjust the close-up view to the
same scene in the panorama view. Click Single Scene Calibraon, and the
calibraon for the selected scene starts.
When the calibraon is complete, click Stop Calibraon to exit. Select
another scene and repeat the calibraon.
4.
Click Save.
4.13.2 Set Panorama Linkage – Manual Calibraon
Steps
1.
Go to Conguraon → Calibrate → Panorama Linkage .
2.
Select the Calibraon Mode as Manual Calibraon. Click Start Calibraon.
3.
Select a scene.
4.
Add calibraon points.
1) Select a No. in Calibraon Parameter list. Click
.
A numbered green cross displayed on the live image.
2) Drag the green cross to a certain posion.
3) Repeat the steps above to add more calibraon points.
Note
●
It is recommended to add at least 9 calibraon points in one scene. For higher tracking
precision, up to 12 calibraon points can be added. Calibraon points should be distributed
evenly in live image, for example, 3 points at far range, middle range, and close range each.
●
It is recommended to put calibraon points at disnct posions in live image (for example,
corners). If no disnct posion is available, you can place something (for example, box, stool,
or people) to mark the posion.
5.
Link the PTZ channel to the calibraon points in panorama view.
1) Select a calibraon point in panorama view.
2) Adjust the PTZ channel to set the center of the close-up view at the same posion as the
calibraon point in panorama view by using the PTZ control buons.
3) Click
to link the current PTZ posions to the calibraon point.
4) Repeat the steps above to link other calibraon points.
6.
Click Start Calibraon to nish the calibraon for the current scene.
7.
When calibraon is complete, click Stop Calibraon to exit.
8.
Click Save.
TandemVu PTZ Camera User Manual
26