Spark Plug Maintains
To service spark p lug:
1. Clean area around s park plug.
2. Remove and in spect spark plug.
3. Inspect electrode gap with wire
feeler
gauge a nd reset spark p lug gap to
0.7 6
mm.
NOTE: Replace spark plug if electrodes are pitted, burned or porcelain is cracked.
Use ONLY re commend ed repla cement plug. See Specifications .
4. Install spa rk plug finger tight, and tighten an additional 3/8 to 1/2 turn using
spark plug wrench.
Valve Clearance
IMPORTANT NO TE: If un comfortable about doing this pro cedure, or the
proper tools are not available, take generator to the nearest service ce nter to have
valve clearance ad
justed.
Check valve c learance after the first fifty-hours of operation. Adjust as nece s s ary.
Intake 0.1 5 ± 0.02mm (cold)
Exhaust 0.20 ± 0.02mm (cold)
Storage
It is recommended to start and run the gen era-tor for 30 minutes, every 30 days. If
this is not possible, refer to the following list to prepare unit for storage.
DO NOT pla ce a storage cover on a hot generator. Allow unit to cool to ro om
temperature before st orage.
DO NOT store fuel fr om one season to another u
nless
properly treated.
Replace fuel container if rust is present.
Rust in fuel will cause fuel system problems.
Cover unit with a suitable protective, moisture resistant cover.
Store unit in a c lean and d ry a rea.
Always store generator and fu el away from heat and ignition sources.