SMFT-1000
Users Manual
38
Surge Protection Device (SPD) Test
The SPD test is a check that the device under test (DUT) works as expected.
To s et :
1. Turn the rotary switch on the PV Analyzer to .
The display shows the default Bypass Diode test mode.
2. Push
for the SPD test mode.
The display shows blank measurements.
3. Use
to open the Set Limit menu and set the pass/fail limit for the diode voltage
measurement.
To set limit:
a. Use
and to select the digit to edit.
b. Use
to change the value.
c. Push
(Back) to return to the SPD test mode.
4. Connect the test leads from the PV Analyzer to the PV Array.
Tip: Push
to see a connection diagram.
a. Connect the blue test lead to one side of the surge protection device.
b. Connect green test lead to the other side of the surge protection device.
5. Push
>1 s. to start the measurement.
Note
While the test results load,
X shows on the display until the test results settle.
When the measurement is complete, the display shows the measured voltage.
6. Push
to save the results to memory.
A confirmation message with ID number shows on the display and then returns to the test
screen.