GAS DRYER INSTALLATION REQUIREMENTSGAS DRYER INSTALLATION REQUIREMENTS
The design of this dryer has been certied by CSA International
for use at altitudes up to 10,000 ft (3,048 m) above sea level
at the B.T.U. rating indicated on the model/serial plate. Burner
input adjustments are not required when the dryer is operated
up to this elevation.
Your dryer can be installed in a basement, laundry room, or
recessed area.
Companion appliance location requirements should also be
considered.
IMPORTANT: Do not install or store the dryer where it
will be exposed to the weather. Proper installation is your
responsibility.
You will need:
A grounded electrical outlet located within 6 ft (1.8 m) of
where the power cord is attached to the back of the dryer.
See “Electrical Requirements.”
A level oor with a maximum slope of 1" (25 mm) under
entire dryer. Installing the dryer on soft oor surfaces,
such as carpets or surfaces with foam backing, is not
recommended.
Electric dryer installation clearances
The location must be large enough to allow the dryer door to
be fully opened.
Additional spacing should be considered for ease of
installation and servicing. The door opens more than 180°.
Additional clearances might be required for wall, door, and
oor moldings.
Additional spacing of 1" (25 mm) on all sides of the dryer is
recommended to reduce noise transfer.
The back of the dryer shall be installed against a wall. Refer
to the minimum installation dimensions/clearances in the
diagrams.
Recessed Area and Closet Installation Instructions
This dryer may be installed in a recessed area or closet. For
recessed area and closet installations, minimum clearances
can be found on the warning label on the rear of the dryer
or in “Dimensions/Clearances.”
WARNING
Explosion Hazard
Keep flammable materials and vapors, such as
gasoline, away from dryer.
Do not install in a garage.
Failure to do so can result in death, explosion, or fire.
Location Requirements The installation spacing is in inches and is the minimum
allowable. Additional spacing should be considered for ease
of installation, servicing, and compliance with local codes and
ordinances.
If closet door is installed, the minimum unobstructed air
opening in the top and bottom is required. Louvered doors with
equivalent air openings are acceptable.
The dryer must be exhausted outdoors.
24 in2
(155 cm
2)
48 in2
(310 cm2)3"
(76 mm)
3"
(76 mm
)
Closet
door
Front
View
Closet
Door
Front
View
Electrical Requirements – U.S.A. only
It is your responsibility:
To contact a qualied electrical installer.
To be sure that the electrical connection is adequate and in
conformance with the National Electrical Code, ANSI/NFPA
70-latest edition and all local codes and ordinances.
The National Electrical Code requires a 4-wire power supply
connection for homes built after 1996, dryer circuits involved
in remodeling after 1996, and all mobile home installations.
A copy of the above code standards can be obtained from:
National Fire Protection Association, One Batterymarch
Park, Quincy, MA 02269.
To supply the required 3 or 4 wire, single phase,
120 V/240 V, 60 Hz AC only electrical supply (or 3 or 4 wire,
120 V/208 V electrical supply, if specied on the serial/rating
plate) on a separate 30 A circuit, fused on both sides of the
line. A time delay fuse or circuit breaker is recommended.
Connect to an individual branch circuit. Do not have a fuse
in the neutral or grounding circuit.
Do not use an extension cord.
If codes permit and a separate ground wire is used, it is
recommended that a qualied electrician determine that
the ground path is adequate.
When installed above 10,000 ft (3,048 m), a four percent (4%)
reduction of the burner B.T.U. rating shown on the model/serial
plate is required for each 1,000 ft (305 m) increase in elevation.
For assistance when converting to other gas types and/or
installing above 10,000 ft (3,048 m) elevation, contact your local
service company.