ANCEL S3000 Car Smoke Leak Detector

User Manual - Page 4

For S3000.

PDF File Manual, 5 pages, Read Online | Download pdf file

S3000 photo
Loading ...
Loading ...
Loading ...
C - Smoke Outlet Port
While set up the unit, the Smoke Delivery Hose need to be mounted onto the Smoke Outlet .
D - Power Socket
While set up the unit, the power cords need to plug into the power socket.
E,F - State Indica�on and Air Control
The <E - LED Indicaon> LED has two states.
RED: Power ON.
GREEN: Pressurized air producon.
While power up the unit, the LED would turn RED.
Press <F - Air Control switch>, the <E - LED Indicaon> would turn GREEN, and the unit start
to generate pressurized air.
Press <F - Air Control switch> again anyme, the <E - LED Indicaon> would turn RED, and
the unit stops generag pressurized air.
G,H - State Indica�on and Smoke Control
The <G - LED Indicaon> LED has three states.
OFF: Smoke generaon not started.
GREEN: Smoke generaon.
RED: Overheat.
While not smoke the unit, the LED would be OFF.
Press <H - Smoke Control switch>, the <G - LED Indicaon> would turn GREEN, and the unit
start to generate smoke.
Press <H - Smoke Control switch> again anyme, the <G - LED Indicaon> would turn OFF,
and the unit stops generang smoke.
While the smoke generag chamber is overheat, for protecon, the smoke generaon
would be halted and the <G - LED Indicaon> would turn RED and restart generang smoke while
the smoke generag chamber cooled down, or you can switch it OFF by pressing <H - Smoke
Control switch> .
I - System Pressure Gauge
The Pressure Gauge displays the output pressure of the machine if block the smoke outlet port,
otherwise it shows the real me pressure of the system been tes.
Pressure Decay Test: This gauge can also be used to determine if a leak exists by switching o
the
<F - Air Control> while the system is under pressure. If the gauge holds the displayed pressure,
there is no leakage. If the displayed pressure starts drops, there is leakage in the system.
J - Flow Meter
The purpose of the ow meter is to provide a quick visual indicaon of the amount of air/smoke
passing through the system being tested. If the smoke nozzle is in a closed system, and there are
no leaks in that system, the ow meter will read zero (ball at boom of sc
ale). As the system is
lled with air or smoke, the ball in the ow meter will slowly fall to the boom of the scale as the
pressure in the system equalizes to the output pressure of the unit. As the ow decreases, the
output pressure will increase. If the ow meter ball never falls to the boom of the scale, there is
leakage or air passing through the system. It is not necessary to use smoke when using the ow
meter to determine if a leak exists.
K - Flow Dial
In many cases exce
ssive smoke exig a leak may make it dit to determine the exact locaon
of the leak. The purpose of the Flow Control Valve is to decrease the amount of smoke exig a
leak so that its posion may be pinpointed without the masking eect of excessive smoke. Turn
clockwise to decrease ow, counterclockwise to increase ow. This valve is also used to lock out
the system under test and observe any pressure decay on the pressure gauge.