cavity used to enclose the gas grill. A propane cylinder can not be stored below the gas grill.
BUILT IN CYLINDER ENCLOSURES: Built in cylinder enclosures which completely enclose the cylinder must
have both of the following:

within 127mm of the top of the enclosure. The opening must have a total free area of more than 130 cm
2
for a cylinder up to 9 kg and 195 cm
2
for a cylinder larger than 9 kg.


2
for a cylinder up to 9 kg
and 100 cm
2
for a for a cylinder larger than 9 kg. The upper edge must be no more than 127 mm above

Every opening must be large enough to permit the entrance of a 3.2 mm rod.
WARNING!
The cylinder valve(s) must be readily accessible for hand operaon. A door on the enclosure to
gain access to the cylinder valves is acceptable, provided it is non-locking and can be opened
without the use of tools.
The enclosure for the LP-gas cylinder must isolate the cylinder from the burner compartment to
provide shielding from radiaon, a ame barrier, and protecon from foreign material, such as
hot drippings. The enclosure cannot be located directly below the grill.
There must be a minimum clearance of 51 mm between the oor of the LP-gas cylinder enclosure
and the ground.
The enclosure must be designed so that the LP-gas cylinder can be connected, disconnected and
the connecons inspected and tested outside the cylinder enclosure. Any connecons that can
be disturbed when installing the cylinder in the enclosure must be accessible for tesng inside
the enclosure.
127 mm
MAXIMUM
25.4 mm
MAXIMUM
OPENING
A
OPENING
B
51 mm
MINIMUM
PARTITION TO ISOLATE
CYLINDER FROM GRILL
NON LOCKING DOOR
864 mm
RECOMMENDED
127 mm
MAXIMUM
CYLINDER SIZE OPENING A AREA OPENING B AREA
Up to 9 kg
130 cm
2
65 cm
2
Larger than 9 kg
195 cm
2
100 cm
2
!