17. INSTALL THE PRESSURE REGULATOR
WARNING
EXPLOSION HAZARD: do not
exceed 25 ft-lbs. of torque when making gas
line connections. Overtightening may crack the
pressure regulator resulting in fire or explosion
hazard.
You must use the gas pressure regulator supplied
with this range.
Shut off the main gas supply valve before
disconnecting the old cooktop and leave it off until
WKHQHZKRRNXSKDVEHHQFRPSOHWHG'RQWIRUJHW
to relight the pilot on other gas appliances when you
turn the gas back on.
For all connections, use a pipe sealant approved by
ORFDOFRGHVDQGUHVLVWDQWWRWKHDFWLYLW\RI/3JDV
Install the pressure regulator in the gas line as close
to the cooktop inlet as possible to allow clearance for
ventilation ducting.
Make sure the arrow on the body of the regulator
is pointing straight up and toward the cooktop. Any
other position will affect the output pressure of the
regulator. This arrow indicates correct flow of gas.
Install a manual gas line shut-off valve in an easily
accessible location.
NOTE: Instead of using solid piping to connect
WRSUHVVXUHUHJXODWRUDQDSSURYHGIOH[LEOHPHWDO
appliance connector may be used between the
shut-off valve and the pressure regulator, if local
codes permit.
If the hard piping method is used, you must carefully
align the pipe. The cooktop cannot be moved after
the connection is made.
Appropriate flare nuts and adapters are required at
HDFKHQGRIWKHIOH[LEOHFRQQHFWRU
TEST FOR LEAKS
WARNING
'212786($)/$0(72&+(&.
)25*$6/($.6'RQRWXVHWKHFRRNWRSXQWLODOO
connections have been leak tested.
3HUIRUPOHDNWHVWSHUWKHIROORZLQJLQVWUXFWLRQV
3XUFKDVHDOLTXLGOHDNGHWHFWRURUSUHSDUHDVRDS
solution of one part water, one part liquid detergent.
2. When all connections have been made, make sure
all cooktop controls are turned to OFF and turn the
gas supply valve to ON.
3. Apply the liquid leak detector or the soap solution
around all connections from the shut-off valve to the
cooktop.
4. A leak is identified by a flow of bubbles from the
area of the leak.
5. If a leak is detected, turn the gas supply off. Tighten
the fitting. Turn the gas on and test again.
If the leak persists, turn the gas supply off and
FRQWDFW\RXUGHDOHUIRUDVVLVWDQFH'RQRWDWWHPSWWR
operate the cooktop if a leak is present.
IMPORTANT: 'LVFRQQHFWWKHFRRNWRSDQGWKH
individual shut-off valve from the gas supply piping
system during any pressure testing of that system
DWWHVWSUHVVXUHVJUHDWHUWKDQSVLJ,VRODWH
the cooktop from the gas supply piping system by
closing the individual manual shut-off valve to the
cooktop during any pressure testing of the gas
supply piping system at test pressures equal to or
OHVVWKDQSVLJ