WORKING CONDITION
1. Medium transportation temperature: 2~+95
2. Max circumstance temperature: +40
3. Medium condition: clean, no solid substance, no mineral & oil substance,
no stickiness.
4. Chem. condition: near neutral, non-cauterization, non-explosion similar
water (glycol max-content: 30%).
5. If you want to use other kinds of liquids, please consult the factory.
6. Max working pressure: 3 bar
7. The pump must be working at a rated voltage range of ±10%. If the
voltage is too low, the pump will come out low speed or hardly start up,
easily heating, lower head and pressure.
PURPOSE AND INSTALLATION PRECAUTIONS
1. The water pump is used for water supply and drainages of rivers, wells,
boilers, etc., such as aquaculture, gardens, hotels, and pots. The boiler,
canteen, high-rise building, and other pressurized water supply conditions
are clean water. The water pump should be close to the water source, the
water suction pipeline shall be as short as possible, and no air leakage is
allowed. Otherwise, water cannot be absorbed.
2. The water pump shall be installed directly above the well as far as
possible, but when the water pump can only be installed far away from the
well, the maximum length between the pipe and the well depends on the
suction head.
Suction height is subject to dry season
Suction height
(m)
7
6
5
4
Horizontal piping
length (m)
14
26
37
49