Smeg P64XGHUE Gas Hob 60 cm

User manual EN pdf - Page 14

For P64XGHUE.

PDF File Manual, 17 pages, Download pdf file

Loading ...
Loading ...
Loading ...
34 - INSTALLATION 91477A862/A
Burner and nozzle specifications tables
The nozzles not provided are available at Authorised Service Centres.
Electrical connection
General information
Check the mains characteristics against the data
indicated on the plate.
The identification plate bearing the technical
data, serial number and brand name is visibly
positioned on the appliance.
Do not remove this plate for any reason.
The appliance must be connected to ground
using a wire that is at least 20 mm longer than
the other wires.
The appliance can work in the following modes:
1 Natural gas G20 - 20 mbar AUX SR RR R UR UR2 int. UR2 ext.
Rated heating capacity (kW)
1.10 1.70 2.60 3.10 3.50 1.00 3.20
Nozzle diameter (1/100 mm)
76 95 115 126 135 73 130
Reduced capacity (W)
400 500 750 900 1600 400 1400
Primary air (mm)
1 0.5 1 1 1.5 2 1.5
2 Natural gas G20 - 25 mbar AUX SR RR R UR UR2 int. UR2 ext.
Rated heating capacity (kW)
1.10 1.70 2.60 3.10 3.50 1.10 3.10
Nozzle diameter (1/100 mm)
73 87 110 120 126 73 120
Reduced capacity (W)
400 500 750 900 1600 400 1400
Primary air (mm)
1 0.5 1 1 1.5 1.5 2
3 Natural gas G25.1 - 25 mbar AUX SR RR R UR UR2 int. UR2 ext.
Rated heating capacity (kW)
1.10 1.70 2.60 3.10 3.50 1.10 3.10
Nozzle diameter (1/100 mm)
76 98 123 135 145 76 135
Reduced capacity (W)
400 500 750 900 1600 400 1400
Primary air (mm)
1 0.5 0.5 1 1.5 1 2
4 Natural gas G2.350 - 13 mbar AUX SR RR R UR UR2 int. UR2 ext.
Rated heating capacity (kW)
1.10 1.70 2.60 3.10 3.50 1.10 3.10
Nozzle diameter (1/100 mm)
100 126 160 175 190 100 175
Reduced capacity (W)
400 500 750 900 1600 400 1400
Primary air (mm)
1 0.5 1 1 1.5 1.5 1.5
5 LPG G30/31 - 30/37 mbar AUX SR RR R UR UR2 int. UR2 ext.
Rated heating capacity (kW)
1.00 1.70 2.60 3.10 3.50 1.00 3.20
Nozzle diameter (1/100 mm)
48 62 76 85 87 48 85
Reduced capacity (W)
400 500 750 1000 1000 400 1400
Primary air (mm)
1.5 1.5 1.5 8 3 4 12
Rated capacity G30 (g/h)
73 124 189 225 254 73 233
Rated capacity G31 (g/h)
71 121 186 221 250 71 229
6 LPG G30/31 - 37 mbar AUX SR RR R UR UR2 int. UR2 ext.
Rated heating capacity (kW)
1.10 1.70 2.60 3.10 3.50 1.00 3.20
Nozzle diameter (1/100 mm)
48 60 73 80 82 45 80
Reduced capacity (W)
450 550 750 1100 1600 450 1400
Primary air (mm)
1.5 1.5 1.5 10 2.5 6 12
Rated capacity G30 (g/h)
80 124 189 225 254 73 233
Rated capacity G31 (g/h)
79 121 186 221 250 71 229
7 Town gas G110 – 8 mbar AUX SR RR R UR UR2 int. UR2 ext.
Rated heating capacity (kW)
1.10 1.70 2.60 3.00 3.50 1.00 3.20
Nozzle diameter (1/100 mm)
126 165 200 230 250 126 230
Reduced capacity (W)
400 500 750 900 1400 400 1200
Primary air (mm)
0.5 0.5 0.5 1 1.5 1 2.5
See General safety instructions.
Loading ...
Loading ...
Loading ...