Grounding
Green
Green
Black
Black
Black
Black
Connect the white (neutral)
wire from receiver to the
white (neutral) wire from the
outlet box with a wire
connector.
White
White
White
White
Connect the black (hot) wire
from receiver to the black (hot)
wire from outlet box with a wire
connector.
Blue
Blue
Fig.10
orange
orange
*** After making the wire connections, the wires should
be spread apart. The white (neutral) conductor from
receiver and outlet box with green (grounding)
conductor on one side; the black (hot) conductor from
receiver and outlet box with the white, black, blue and
orange conductor from receiver and motor on the
other side of the outlet box.
*** The wire connection points should be turned upward
and pushed carefully up into outlet box.
Connect the blue wire from
receiver to the blue wire from
motor (This is for main light
control) with a wire connector
Connect three
ground wires (Green,
or bare copper) coming
from outlet box,
downrod and hanging
bracket with a wire
connector.
Connect the black
wire from receiver
to the black wire
from motor (This is
for fan control)
a wire connector
Connect the white
wire from receiver
to the white wire
from motor
wire connector
Connect the orange wire from
receiver to the orange wire
from motor (This is for accent
light control) with a wire
connector
Fig.9
Move ground wires (a), outlet box wires (b), and
motor wires (c) away from the center of the hanger
bracket. Then slide receiver through hanger
bracket as shown. Antenna end first, until it is
centered. Finally, cut motor wires (c) to length
needed for connections.
Code example:
1-ON 2-OFF 3-ON 4-OFF on both DIP
Switches.
Note: If you have two ceiling fans
with 2 remote control units, set 2
different codes for each set of
transmitter / receiver.
Fig.8
Antenna
DIP Switch
Transmitter
Receiver
PAGE: 6 / 11
Both the transmitter and receiver have a 4-key
unit code on each DIP Switch (Fig.8) and by
default, all keys are pre-set to the "off" position.
This means that the transmitter and receiver are
already paired together. However, if you have
multiple fans and remote controls and want to
avoid interference between them, you can "pair"
other transmitters and receivers together by
adjusting the DIP switches, so the same
numbered keys are in the "ON" position
on both (Fig.8a).
Note: The ceiling fan may work abnormally
if there is interference from other remote
controls.
SUR
ON
ON SUR
Hanger Bracket
Receiver
Antenna
220104
Loading ...