Loading ...
Loading ...
Loading ...
12
CONVERSIONS
9) NATURAL GAS TO PROPANE GAS
CONVERSION PROCEDURE
Appliance models: Gas stainless steel hotplate
models:
CG905WXC 5 Burners
CG905WXFFC 5 Burners
1. Remove each burner cap and burner skirt.
2. Remove the Natural Gas main injector with a
7 mm/VF tube spanner and replace with the
appropriate size Propane Gas main injector for
each burner. The following injector sizes are
required for Propane Gas:
Burner Main injector
Wok 0.94 mm
Rapid 0.91 mm
Semirapid 0.70 mm
Auxiliary 0.53 mm
3. Remove the control knob, with a thin shaft blade
screwdriver down the centre of each gas valve
shaft, screw the by-pass injector fully clockwise.
4. Shut off gas supply to the appliance.
5. Disconnect gas inlet pipe from the Natural Gas
Regulator.
6. Remove the Natural Gas Regulator from the
appliance.
7. Fit the Propane Gas test point inlet fitting
supplied in the conversion kit.
8. Connect the gas supply to the inlet fitting.
9. Check for gas leaks. Do not use a naked flame
to check for gas leaks.
10. Adjust the gas pressure to 2.75 kPa.
11. Test the appliance on both high and low flame
for each burner and check the gas pressure. If the
burner fails to remain alight or the flame is not
stable on the simmer setting, adjust the by-pass
screw until flame is stable.
12. If not already removed, remove the Only for
use with Natural Gas” label adhered to the bottom
panel near the gas connection.
13. Fit the new data label included in the gas
conversion kit.
Loading ...
Loading ...
Loading ...