8) PROPANE GAS TO NATURAL GAS
CONVERSION PROCEDURE
Appliance models: Gas stainless steel hotplate
models:
CG905WXC 5 Burners
CG905WXFFC 5 Burners
1. Remove each burner cap and burner skirt.
2. Remove the Propane Gas main injector with a
7 mm/VF tube spanner and replace with the
appropriate size Natural Gas main injector for each
burner. The following injector sizes are required for
Natural Gas:
Burner Main injector
Wok 1.76 mm
Rapid 1.55 mm
Semi Rapid 1.20 mm
Auxiliary 0.90 mm
3. Shut off gas supply to the appliance.
4. Disconnect gas inlet pipe from the Propane Gas
test point inlet fitting.
5. Remove the Propane Gas test point inlet fitting
from the appliance.
6. Fit the Natural Gas Regulator supplied in the
conversion kit.
7. Connect the gas supply to the Regulator.
8. Check for gas leaks. Do not use a naked flame
to check for gas leaks.
9. Adjust the gas pressure to 1.00 kPa.
10. Remove the control knob, with a thin shaft blade
screwdriver down the centre of each gas valve
shaft, screw the by-pass injector anti-clockwise.
Test the appliance on both high and low flame for
each burner. If the burner fails to remain alight or
the flame is not stable on the simmer setting, adjust
the by-pass screw, until flame is stable.
11. If not already removed, remove the “Only for
use with Propane Gas” label adhered to the bottom
panel near the gas connection.
12. Fit the new data label included in the gas
conversion kit.