Loading ...
Loading ...
Loading ...
34
- All Other Markets
NOTE:
(*) Measure burner operating pressure at Operating Pressure Test Point (Lower -
Out) on gas control valve, with both burners operating at ‘High Flame’ setting.
(**) TOWN GAS Option is only available with specific ex-factory built Town Gas
Models, which can also be converted to any other gas. Standard models can only be
converted between Nat. Gas, LP Gas and Butane, but not Town Gas.
Refer to ‘Gas Conversion and Specifications’ in this manual for further details.
Main Burner Injectors
Ø 3.10mm Ø 6.30mm
Pilot Burner Injectors
0.62 0.75
Pilot Screw Adjustment Full Out (CCW) Full Out (CCW)
Burner Operating Pressure (*) 0.98 kPa 0.50 kPa
Supply Pressure 1.13 - 2.0 kPa 0.75 - 1.50 kPa
Main Burner Injectors
Ø 1.80mm Ø 1.70mm
Pilot Burner Injectors
0.35
Pilot Screw Adjustment 1½ turns out (CCW)
Burner Operating Pressure (*) 2.50 kPa
Supply Pressure 2.75 - 3.00 kPa