Installation and Placement
Importance of proper ventilation
For placement of the amplifier, keep the following in mind:
Make sure that air can circulate freely from left to right for adequate ventilation. There are vents on the sides.
The temperature of the rack should be controlled to ensure that amplifiers are not exposed to ambient temperatures
exceeding 40° C (104° F).
Do not cover or block amplifier vents.
Do not place the amplifier in an enclosed space, such as a cabinet.
Make sure the chassis is protected from heat and kept away from direct heat sources, such as heating vents
and radiators.
CAUTION: Do not allow the chassis to exceed the maximum operating temperature of 40° C (104° F). Be aware of
conditions in an enclosed rack that may increase the temperature above room-ambient conditions. If the amplifier
becomes too hot, it will go into a thermal protection mode and mute all outputs.
Removing rack-mount ears
Rack-mount ears can be removed by removing the three screws from each rack-mount ear.
Placing on a flat surface
The amplifier can be placed on a flat, stable surface like a table, counter, or shelf. The rack-mount ears can be removed
and plastic feet (included with the amplifier) can be installed to protect the surface area and prevent the chassis
from sliding.
Note: When installing the amplifier in an office, conference room, or classroom, carefully place it in a way that minimizes the audible
affects of the internal cooling fan of the amplifier. It is recommended to place the amplifier below ear level, in a corner, with the
fan inlet (left side) pointing away from the seating area.