Gas Connecting
WARNING: Never use an open flame to test for gas leaks, because death, personal injury
and/or property damage can result. The water heater and its gas connections MUST be leak
tested at normal operating pressures before the uint is placed in operation.
1. Use shifting wrenches to attach supplied gas regulator (with brass connector already attached) to
the appliance and connect to the bottom of the appliance marked “Gas inlet”. Do not over tighten.
Over tightening may causing a gas leak! Ensure that you use supplied washers on all connectors
and check for any gas smell. Please connect with torque force between 20-28N/m.
2. Please always use the cylinder at an upright position for vapor withdrawal. Connect the certified
gas regulator with LP gas supply cylinder by hand. Connect the regulator hose to the heater gas
inlet fitting by wrench.
Connecting to cylinder:
Connect the gas regulator to the
gas cylinder, tightening using
two fingers support posts.
Connecting to cylinder:
Disconnect the gas regulator
from the gas cylinder, tightening
using two fingers support posts.
Already attached
to the gas inlet
Don’t around any
sealing tapes on
the thread
3. Water outlet :
Attach the water output device (shower head) to the fitting marked “Water outlet”. DO NOT OVER
TIGHTEN! Tighten by hand only. (The shower hose already comes with gaskets inside, extra
gaskets are available as a spare.)