Technical datasheet
Tumble dryer:
Heating:
PT 8807
Steam (D)
Legend:
Abbreviations in bold type:
Connection required
en - US
Abbreviations in circle with dashes:
Connection optional or required depending on model version
Optional extras:
BS
Concrete base
Quality and density of concrete must comply with load.
Concrete base must be firmly secured to floor!
Recommended height
4“
100 mm
Minimum height
2“
50 mm
Minimum width
36
900 mm
Minimum depth
48
1200 mm
DAV
Steam
connection
valve
The steam connection valve to regulate the steam supply
must be provided on site.
The following valves can be ordered separately as electric
steam valves or as pneumatic steam valves.
Pneumatic steam valve (PND)
Regulatable steam pressure
0 - 145 psi
0 - 1000 kPa
Connection gauge
½“
Supply point and pneumatic valve controls must be provided on site.
Machine connections:
Electrical
connection
Voltage
3 AC 208 V
Frequency
60 Hz
Rated load
6487.4 BTU/h
1.9 kW
Fuse rating
3 x 10 A
Connection cable, min. cross-section
4 x AWG 16
4 x 1.5 mm²
(Connection cable to be ordered separately)
Electrical connection must comply with national regulations.
Connection using multi-pole wall socket in compliance with IEC/EN 60309 and IEC/EN 60947 is
recommended in order to simplify electrical tests.
If machines are hard-wired, a multi-pole switch must be provided on site.
A wall socket or isolator must be accessible after installation.
Installation plan: PT 8807 D
Date: 29-Jan-2015 Page: 13