Tumble dryer
PT 8807 D (Steam)
en - US
05.15 M.-Nr. 10 126 430
background
It is essential to read the operating and installation instructions before
installing, commissioning or using the machine.
This avoids the risk of accidents or damage.
All rights reserved
M.-Nr. 10 126 430
2
background
PT 8807 D en - US
Machine dimensions
(measurements in inches)
3
background
en - US PT 8807 D
M
achine connections (measurements in inches)
4
background
PT 8807 D en - US
Machine c
onnections (measurements in inches)
5
background
en - US PT 8807 D
Standard
installation (measurements in inches)
6
background
PT 8807 D en - US
Option:
Installation on concrete platform (BS) (measurements in inches)
7
background
en - US PT 8807 D
Machine dimen
sions (measurements in millimeters)
8
background
PT 8807 D en - US
M
achine connections (measurements in millimeters)
9
background
en - US PT 8807 D
Machine c
onnections (measurements in millimeters)
10
background
PT 8807 D en - US
Standard installation
(measurements in millimeters)
11
background
en - US PT 8807 D
Option:
Installation on concrete platform (BS) (measurements in millimeters)
12
background
Technical datasheet
Tumble dryer:
Heating:
PT 8807
Steam (D)
Legend:
Abbreviations in bold type:
Connection required
en - US
Abbreviations in circle with dashes:
Connection optional or required depending on model version
Optional extras:
BS
Concrete base
Quality and density of concrete must comply with load.
Concrete base must be firmly secured to floor!
Recommended height
4“
100 mm
Minimum height
2“
50 mm
Minimum width
36
900 mm
Minimum depth
48
1200 mm
DAV
Steam
connection
valve
The steam connection valve to regulate the steam supply
must be provided on site.
The following valves can be ordered separately as electric
steam valves or as pneumatic steam valves.
Pneumatic steam valve (PND)
Regulatable steam pressure
0 - 145 psi
0 - 1000 kPa
Connection gauge
½“
Supply point and pneumatic valve controls must be provided on site.
Machine connections:
Electrical
connection
Voltage
3 AC 208 V
Frequency
60 Hz
Rated load
6487.4 BTU/h
1.9 kW
Fuse rating
3 x 10 A
Connection cable, min. cross-section
4 x AWG 16
4 x 1.5 mm²
(Connection cable to be ordered separately)
Electrical connection must comply with national regulations.
Connection using multi-pole wall socket in compliance with IEC/EN 60309 and IEC/EN 60947 is
recommended in order to simplify electrical tests.
If machines are hard-wired, a multi-pole switch must be provided on site.
A wall socket or isolator must be accessible after installation.
Installation plan: PT 8807 D
Date: 29-Jan-2015 Page: 13
background
Equipotential
bonding
Connection with male thread
3/8“ x 1 3/8“
10 mm × 35 mm
Connection with washers and nut
3/8“
M 10
Accessories to be ordered separately.
If necessary, equipotential bonding with good galvanic contact must be provided in accordance with
all appropriate national and local regulations.
Steam
connection
Steam pressure
87 - 145 psi
600 - 1.000 kPa
Boiling point
329 - 363 °F
165 - 184 °C
Steam supply capacity
156.5 lbs/h
71 kg/h
Connection thread (on site)
½" internal thread
Supply lead Steam valve Length
19 11/16“
500 mm
Steam valve, steam filter and steam fancet must be provided on site.
The steam valve should be installed close to the steam connection. Note installation instructions for
steam-heated Miele tumble dryers.
Condensate
connection
Connection thread (on site) ½" internal thread
Steam valve, steam filter and steam faucet must be provided on-site.
Installation of the steam trap needs to allow complete drainage of the heater element during
machine downtime. This means, no condensate is left in the heater element. Installation of an
inverted bucket steam trap is recommended.
Air outlet
Max. nominal air flow in vented mode
39200 cu ft/h
1110 m³/h
Max. permissible pressure loss
6.3 psf
300 Pa
Connection on machine side (ext. diameter)
5 15/16
150 mm
Connection pipe provided on site (int. diameter)
5 15/16
150 mm
Max. temperature
176 °F
80 °C
As relative humidity inside the vent duct can be as high as 100%, suitable measures must be taken
to prevent a backflow of condensate into the machine.
Air intake
Standard connection: Air intake from installation site
Recommended unobstructed air intake into room
(corresponding to 3 times the vent cross-section of
machine)
82.31 in²
531 cm²
A sufficient supply of fresh air should be ensured to
replace the air extracted.
Alternative connection: Ducted air intake (from outside
building)
Connector on machine (int. diameter)
6 5/16
161 mm
Connection pipe provided on site (ext. diameter)
6 5/16
160 mm
Lid removal exposes live components! For safety reasons,
the pipe connected for central air intake should be at least
35 7/16” [900 mm] long and secured using two screws.
Installation plan: PT 8807 D
Date: 29-Jan-2015 Page: 14
background
Fittings
(supplied)
Without base
2 x clamps
2 x screws DIN 571 (Ø x length)
1/4“ x 1 9/16“
6 mm x 40 mm
2 x rawl plugs (Ø x length)
3/8“ x 2“
10 mm x 50 mm
Machine must be bolted to the floor!
Fixing materials for floor screed have to be provided on
site.
On concrete platform
2 x clamps
2 x screws DIN 571 (Ø x length)
1/4“ x 1 5/8
6 mm x 40 mm
2 x rawl plugs (Ø x length)
3/8“ x 2“
10 mm x 50 mm
Machine must be bolted to the platform!
Fixing materials for floor screed have to be provided on
site.
Machine data
Width
47 1/2
1206 mm
Depth
54 1/2
1384 mm
Height
64 9/16
1640 mm
Casing width
47 1/4
1200 mm
Casing depth
50 3/8
1279 mm
Minimum width of delivery access to installation site
48
1220 mm
Recommended rear wall gap (measured to front of
machine)
70 7/8
1800 mm
Min. wall gap (to rear edge of lid)
19 3/4
500 mm
Net weight
701.1 lbs
318 kg
Dynamic floor load, max.
834 lbf
3708 N
Average heat dissipation
(depends on ambient room temperature and selected
program)
3692 BTU/h
1082 W
Noise level
73.6 dB (A)
Sound pressure level
(measured at a distance of 39 3/8” [1 m] from the
machine and at a height of 63” [1.6 m])
62 dB (A)
Installation should only be carried out by authorized installers in accordance with all local and national regulations!
Follow installation instructions when installing machine! All rights reserved.
Installation plan: PT 8807 D