THREE-WIRE CONDUIT CONNECTION
WHITE IF
BLACK EQUIPPED
BLACK ) t
LEAD _
i
GROUND
STRAP
7
JUNCTION
BLOCK
RED
ADAPTOR
BLOCKS
WHITE
LEAD
LEAD
STRAIN
RELIEF
CLAMP
POWER CORD
& NUT
BRACKET
1201240 or 240 VAC
If local codes do not allm_ grounding
through tile neutral, rel_r to tile
illustration belm_ of FOUR-WIRE
CONDUIT CONNECTION.
NOTE: The power cord bracket will have
to be reversed for conduit installations.
Detach the bracket and flip its orientation.
Reatiach the bracket to the range so the
conduit will pass through the smaller hole.
1. Remoxe the top nuts on the junction
block studs.
2. Tighten the back nuts.
3. Install the terminal adaptor blocks lbr
bare wire connection. Use the top nuts
removed earlier in step 1.
4. Install the three-wire conduit and an
appropriate strain relief clamp through
the hole in the power cord bracket.
5. Insert the red and black leads into the
outer blocks and the white lead into the
center block. Tighten the set screws.
6. Secure the strain relief clamp around the
conduit and tighten the nut against the
power cord bracket.
BLACK
BLACK
LEAD_
CUT -_
GROUND
STRAP
J
GROUND
LEAD
/"
POWERCORD
BRACKET
JUNCTION
BLOCK
__0_7_ _ITORWQHITEpI F D RED RED
\ _ /._ LEAD
120/240 VAC aNUT
Effective January l, 1996 the National
Electrical (;ode requires that ne_ construction
(not existing) utilize a 4-conductor connection
to an electric range.
NOTE: A 4-conductor connection is to be
used when the appliance is installed in a
mobile home or when local codes do not
permit grounding through the neutral.
FOUR-WIRE CONDUIT CONNECTION
NOTE: The power cord bracket will have
to be reversed for conduit installations.
Detach the bracket and flip its orientation.
Reattach the bracket to the range so the
conduit will pass through the smaller hole.
1. Remo_e the top nuts on the junction
block studs. Then, tighten the back nuts.
2. Cut the ground strop as close to the
jtmction block as possible and at the
lower section with upturned sides.
3. Install the fore:wire conduit and an
appropriate strain relief clamp through
the hole in the power cord bracket.
4. Use the section of ground strap with
upturned sides and the ground screw to
connect the ground lead below the
junction block.
5. Install the terminal adaptor blocks lbr
bare wire connection. Use the top nuts
removed earlier in step 1.
6. Insert the red and black leads into the
outer blocks and the white lead into the
center block. Tighten the set screws.
7. Secure the strain relief clamp around the
conduit and tighten the nut against the
power cord bracket.
13