INSTALLATION
Danger
All electrical wiring from the motor to
the rangehood should be kept inside
the roof space.
Note
* The Isodrive
®
motor system does not
include the roof seal kit, ring clamp
or the support straps.
Note
Please see Isodrive
®
installation guide
for motor installation information.
SYSTEM OVERVIEW GUIDE FOR CCSURF2S AND CCINARTS
1. Isodrive
®
Motor/s
2. Roof Seal Kit (Dektite) (Not supplied)*
3. Support Straps (Not supplied)*
4. Attach Flexi Duct to Bell-Mouth Adaptor using
ring clamp. Please DO NOT rip the ducting.
5. Isodrive
®
Motor Power Lead (Male Plug)
6. Rangehood to Isodrive
®
Motor Lead
(Female Plug)
7. Mains Power Lead (Male Plug, 10 Amp)
8. Flexi Ducting must be pulled taut.
DO NOT crush or kink the ducting.
9. Connect exi ducting to the outlet
on rangehood using ring clamp.
Please DO NOT rip the ducting.
10. Y -joint
Pictures are for illustrative purposes only, not to scale.
Refer A
2
3
4
5
6
7
8
9
1
Single Motor Installation
1
2
3
4
5
6
10
7
8
9
Twin Motor Installation
Rangehood to
Motor power
leads are to be
hard wired by
an electrician.