7
 An isolating switch is fitted within 2 m of the appliance, but not on the appliance and in such a
position that the user does not have to reach across the cooking surface.
 Supply cord shall be oil-resistant, sheathed flexible cable and not lighter than ordinary
polychloroprene or other equivalent synthetic elastomer sheathed cord (as per AS/NZS 3191 part
2.10.11. or IEC 60245-IEC-57) e.g. HO5 RN-F Type.
 The branch supply line shall be individually overload protected to the correct current rating and
the supply chord shall be protected against any mechanical or thermal damage.
 A grommet is fitted around the wiring entry hole into the appliance.
 All wiring connections must be tight.
Refer to the appropriate wiring standards for the size of cable that is to be supplied to an appliance for the
current drawn on that line.
NOTE: ALL ELECTRICAL CONNECTIONS MUST ONLY BE CARRIED OUT BY AN AUTHORISED
PERSON.
1. Remove either the left or right hand side panel to allow access to the electrical connection terminal
block. Fit the cable through the small grommet located at the rear of the unit and connect to the
terminals as marked.
2. If required, the appliance can be connected to two 13 or 15 amp single phase supplies by removing
the insulated wire loom between the left and right hand terminal blocks. Independent supplies can
then be connected to each side.
3. The operating voltage of the
salamander is stated on the rating
plate affixed to the right hand side
panel front bottom corner. This
information is also shown in the
‘Specifications’ Section of this
manual. Ensure that the available
voltage is correct.
NOTE:
 This appliance must be grounded / earthed.
 Fixed wiring installations must incorporate an all-pole disconnection switch.
1. Before leaving the new installation, check that all the connections are correct and, and that the unit
functions in accordance with the operating instructions.
2. Check the current draw and loading for the equipment. Refer specification section for correct
electrical requirements.
NOTE:
 If for some reason it is not possible to get the unit to operate correctly, turn off the
electrical power supply and contact a qualified service person. The supplier of this
unit will be able to recommend a suitable person.
 Make sure that the electrical supply is turned off before any service or maintenance
work is carried out.
Rating Plate
THIS APPLIANCE MUST BE EARTHED. IF THE SUPPLY CORD IS DAMAGED, IT MUST BE REPLACED BY A SUITABLY
QUALIFIED PERSON IN ORDER TO AVOID A HAZARD.