6
This unit must be installed on a non-combustible wall or tailored stand with the following clearances:-
NOTE: Top clearances can be reduced where local fire protection system is provided, if
allowed by the local regulations.
NOTE: Only non-combustible materials can be used in close proximity to this appliance.
1. Fix the wall mounting bracket to the wall with
six screws, in such a position that the top of
the bracket is level and at least 945 mm (38”)
above any surface beneath the unit. This will
ensure that the bottom of the Salamander is at
least 600 mm (24”) above any surface.
2. Fit the two black plastic spacers to the top
rear corners of the unit. Leave them
unscrewed by approximately 5 mm.
3. Fit the two adjusting screws / bolts into the
nutserts at the bottom rear corners of the
unit. These should protrude approximately 30
mm from the rear of the Salamander.
4. Lift the Salamander onto the wall bracket,
lining up the black plastic spacers on the
salamander with the mounting notches in the
bracket.
5. Lower the Salamander onto the mounting bracket.
6. Tighten the black spacers securely and adjust the
levelling screws/bolts to ensure that the unit is level.
~ 5mm
~30mm
Left/Right hand side 50mm 0mm
Rear 50mm 0mm
Extraction Hood 200mm
Ceiling (subject to all local regulation requirements) 300mm
Grease Arresting Filter 400mm