HOMCOM 823-041V80CW 8,000 BTU Portable Air Conditioner Fan w/ Remote

Assembly Instructions - Page 15

For 823-041V80CW.

PDF File Manual, 39 pages, Read Online | Download pdf file

823-041V80CW photo
Loading ...
Loading ...
Loading ...
15
2. Anti-frozen protection function (Optional)
When the ambient temperature Tr22ºC and the compressor runs continuously for 50
minutes, the compressor will stop running - the fan will be forced to run at high speed. The
fan speed indicator on the display board can be switched. After five minutes, the air
conditioner resumes normal operation.
3. Delay protection function of compressor
The unit oers restart protection for the compressor - it may start immediately when the
unit is on for the first time. There is a three minute delay to the restart protection after
compressor is shut down.
4. Coil and room temperature sensor failure:
1) Detect sensor failure at the beginning of turning on/off the unit.
2) When a sensor failure is detected at the beginning of turning the unit on, it will
immediately enter the failure state. If it returns to normal at this time, it will enter the
standby state.
AIR CONDITIONER USE
IMPORTANT: If the air conditioner has been tilted on its side, wait 24 hours before turning
on the air conditioner to allow the oil to return to the compressor. This will prevent it from
failing prematurely.
Hold handles on side panels to move the unit in upright position.
NOTE:
● Do not hold the louver.
● Ensure the unit is upright when handling or moving.
● Before moving or handling, drain the water in the unit completely to prevent a leakage.
DRAIN THE INTERNAL WATER
You will need a small pan to catch the water coming out of the tank. Once the tank is
empty, the unit will resume operation within a few minutes.
MANUAL DRAINAGE
1. When the water is full and the unit shuts down, turn off and unplug the unit.
2. Put the tray below the water outlet at the back of the unit.
3. Screw off the drain cover and unplug the stopper, so water can flow into the tray.
4. Plug in stopper and screw the drain cover tightly onto water outlet after drainage.
Loading ...
Loading ...
Loading ...